Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 44

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest about 3 years ago in Help / Documentation / Videos 0 Declined

Association of Multiple Tags That Represent Same Measurement

As a PI admin, I would like to associate mutiple tags together that represent the same measurement at different time periods SO THAT users see one set of data together instead of the old data in the old tag and the new data in the new tag after DC...
Guest about 3 years ago in Data Archive 0 Declined

Show the AF SQL hostname server in SMT

No description provided
Guest about 3 years ago in Data Archive 0 Declined

PI SMT: some plugins missing features for future data

Certain plugins in PI SMT do not have features to support future data 1. Snapshot and Archive Statistics (is available only through piartool) 2. Current Data does not subscribe to timeseries in Update Manager 3. Stale and Bad tags
Guest about 3 years ago in Data Archive 0 Declined

Store PI Data Archive information in an SQL Server database

Most of the PI Data Archive information that is accessible from PI System Management tools is perfect for a relational database: PI Identities, PI Mappings, PI Point attributes, PI Message Logs, etc. Moving all of this to an SQL Server database w...
Guest about 3 years ago in Data Archive 1 Declined

Increasing the dynamic range of compressed data

I see too often customers struggling to find the right exception and compression settings. When exception/compression are not well defined, they end up having too many values or missing values, what causes a lot of problems when the affected tag i...
Guest about 3 years ago in Data Archive 0 Declined

Link tuning parameters to the UOM database

Many of the tuning parameters have units, but the unit can only be found in the tuning parameter's description and is not written consistently (sometimes written in full, sometimes abbreviated, sometimes written as a symbol). Linking the tuning pa...
Guest about 3 years ago in Data Archive 0 Declined

Being able to activate the Log of abnormally long request made to the PI Data Archive

It would be helpful to determine which users or applications made heavy requests to the Data Archive Server. This could be an option to be activated or not. Logging the ip, user identity, concerned tags, duration of the request Those information a...
jerome.boudon about 3 years ago in Data Archive 0 Declined

Store multiple events at the same timestamp

I have a particular application for storing partial discharge events into the PI Server.  Many of the events are at the same timestamp, which result in multiple events at the same time.
Guest about 3 years ago in Data Archive 1 Declined

process book should have the accessibility of pi data link reports

No description provided
Guest about 3 years ago in Help / Documentation / Videos 1 Declined