Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 135 of 1341

Allow bi-temporal data archiving

PI DA Server should allow for more flexibility in terms of the format of archived data. A big advantage would be if PI could archive two timestamps per event. One timestamp will come from whatever the data source is (PI Interfaces, fiels devices, ...
Guest about 3 years ago in Data Archive 2 Declined

Thresholds for PI Points

It would be nice to have threshold attributes for pi points. Then we could configure that values received from the source outside this limits would be ignored (not stored), substituted by the respective threshold value or even by an "Over\Under Ra...
Guest about 3 years ago in Data Archive 2 Declined

Event mode that applies NoReplace to snapshot as well

Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest about 3 years ago in Data Archive 1 No status

Method to backup and restore PI Points only

The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.
Guest about 3 years ago in Data Archive 0 No status

Negative numbers in digitalsets

Negative numbers in digitalsets for all PI interface and skip numbers, basically that the digitalset is like the enum of AF
Guest about 3 years ago in Data Archive 1 No status

PI Server should recover from any ungraceful shutdown

While the recovery mechanism for queue corruption is much more robust on newer version of PI Data Archive compared to previous versions, there are still few cases where PI Data Archive does not fully recover from ungraceful shutdowns. PI Server sh...
Guest about 3 years ago in Data Archive 0 Declined

Reduce archive file size by eliminating unused record numbers

Background: On a Data Archive where many points have been deleted, there will be many unused record numbers. Since the size of an archive file is tied to the highest existing record number (for performance reasons), this can result in archive file...
Guest about 3 years ago in Data Archive 5 Declined

Use of aliases for tag names

Allow the creation of tag name aliases.  This would allow us to present more user friendly option for tag name searches.  It would also help present a standardized tag name to users for tags from sources that don't follow our standard ta...
Guest about 3 years ago in Data Archive 1 Declined

Ability to Identify Critical (e.g. GxP) PI Tag in SMT

A checkbox or some mechanism to identify Critical data point (e.g GxP) in SMT. * can be used for search filter to separate critical vs. non-critical data (gxp vs non-gxp) * possible additional layer of confirmation/prompt prior deletion (?)  ...
Guest about 3 years ago in Data Archive 1 No status

Built-in feature to automatically move archive files past a certain age to a different directory

Automatically move archives from a disk to another based on their age. Use case: I only want to keep the last 2y of data on a SSD and the remaining will be stored on a regular disk. My use case can be achieve using the example PowerShell script l...
Guest about 3 years ago in Data Archive 0 No status