Ability to view Instrument Tag and Point Source attributes within PI SMT > Data > Current Values pane

Feature request would be to include Instrument Tag and Point Source attributes to be view-able through the Data > Current Values pane of PI SMT.  This would allow administrators and users the ability to quickly diagnose and/or trace PI Poi...
Guest about 3 years ago in Data Archive 0 No status

Compress archives that are backed up using "Copy"

Currently, when a "copy" backup occurs, the archives are copied as-is. Archive files take up a lot of space, but they also compress very well (if you deleted a bunch of tags without creating as many new ones), and since archive backups are rarely ...
Guest about 3 years ago in Data Archive 0 No status

Improve PI Server Installation kit: disk space requirements should include the minimal PI Backup

When calculating the disk space requirements on a recent upgrade the drive was expected to have only 138 MB installed. But the install failed due to not enough disk space on the drive because the minimal backup needed a certain amount of disk spac...
Guest about 3 years ago in Data Archive 1 No status

PI AF Link & PIBatch - Ability to uninstall it

PI AF Link is not included in PI 2018 but it would be good to be able to remove the link during an upgrade. (not possible today https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000027668). Same for PIBatch which cannot be unins...
Guest about 3 years ago in Data Archive 1 No status

AI Detection for Stale Points

As a PI System administrator, it would be helpful if the PI Server had an artificial intelligence or machine learning system which could recognize the normal updating patterns of a PI Point and report when a tag was not receiving updates properly ...
Guest about 3 years ago in Data Archive 0 No status

Provide a MUI Kit for the Data Archive / SMT

Provide a MUI Kit for the Data Archive / SMT
David Scott almost 2 years ago in Data Archive 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest about 3 years ago in Data Archive 1 No status

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li about 2 years ago in Data Archive 0 No status

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest about 3 years ago in Help / Documentation / Videos 0 Declined

Add information about analyses are handled in derived templates and overriding templates

So there is absolutely nothing in the PSE user guide about how analysis templates are handled in derived templates. And while it appears that it is possible to override an analysis in the base template by creating one with the same name, there is ...