Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 383 of 1341

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Guest almost 3 years ago in Analytics & Calculations 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Guest 12 months ago in Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach 12 months ago in Analytics & Calculations 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest almost 2 years ago in Analytics & Calculations 0 No status

ProcessBook - Add Pulp and Paper Symbol Library

Add Pulp and Paper Symbol Library, black Liquor  Evaporators, Lime Kiln, , Digester Batch equipaments.
Guest about 3 years ago in General 0 Declined

Add additional highlight for Knowledge Base Articles that has a confidence of "Not Validated"

add additional highlight on the external articles that are "Not Validated". e.g. Red highlight on the confidence section or highlight on the title name. This would allow the reader to pay more attention that the proposed in solution section of the...
Guest about 3 years ago in General 0 No status

Add SI-Units to UOM

The UOM Database is incomplete. Important units are missing. Please add at least the standard SI units or provide a library/xml-file which has the SI Units included.
Guest about 3 years ago in General 0 No status

Polybase Support with PI SQL Client

Creating a Polybase External Table with a PI SQL Client connection via ODBC causes query errors showing only it only supports column-wise binding. Polybase attempts to utilize row-wise binding which is not supported. Developers and customers have ...
Guest about 3 years ago in General 0 No status

Provide a way to add Haystack, Brick or ASHRAE 223 meta data markers/tags to PI points or within AF.

Commonly used fault reporting software, such as SkySpark, visualization, GIS and Advanced Analytics applications are requiring metadata/markers embededded in the tags in addition to Tag Name, Timestamp and Value. Not having a native way to add the...
Guest about 3 years ago in General 1 No status

Preserve variable-attribute mapping upon attribute path change

Currently, if a variable is mapped to an attribute and the attribute's AF path changes, the variable must be remapped to the attribute. Instead of relying on the attribute's full path to identify the attribute, each attribute should be identified...
Guest about 3 years ago in Analytics & Calculations 5 Declined