Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 370 of 1341

Allow Asset Analytics to output to annotations

As someone who has migrated our calculations from PI ACE to Asset Analytics, we need to be able to annotate various calculation outputs in the same way we were able to with PI ACE. Please enable analyses to output annotations to various PI Tags in...
Guest about 3 years ago in Analytics & Calculations 1 No status

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest about 3 years ago in Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Guest 9 months ago in Analytics & Calculations 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
Guest about 3 years ago in Analytics & Calculations 1 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Guest over 1 year ago in Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Guest over 1 year ago in Analytics & Calculations 0 No status

Have an option in AF Security to not pass down database security to newly created objects

Use case: We want to give a user read access to a single element. All future elements created inherit the Database level Security, meaning the user will also have read access to all future created elements.
Guest about 3 years ago in Security 0 Declined

Hide Certain PI Point Attributes from Users

Implement a way to hide the contents of a PI point attribute, specifically the Instrumenttag attribute. With many PI interfaces, the InstrumentTag attribute will store the IP address of the source, and we (as well as many other utilities) have a r...
Guest about 3 years ago in Security 1 Declined

User rights for viewing analytics

In many cases analytics should not be visible to everyone having right to view an AF-Database. Should be possible to direct whom should have view access to analytics. This is an extension to the obivious right to change analytics :)
Guest about 3 years ago in Security 2 No status

Security tool that allows management of PI Data Archive, Vision, and AF security settings

PI System Administrators would benefit from a client or PI SMT extension that supports auditing and modifying user access. This includes mapping Active Directory roles to PI Identities, managing PI Database and Point access, managing AF Database a...
Guest about 3 years ago in Security 0 No status