Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 466 of 1341

Sampled Data with Analysis Data Reference

Customer would like to have Sampled Data with Analysis Data Reference (periodic values output) without creating tags as output for the Analysis.
Guest about 3 years ago in Analytics & Calculations 2 Declined

Basic GIS Support: in AF and Analytics

Considering that AF has latitude and longitude traits for elements and already supports files as attributes, would it be possible to provide basic GIS support? The file attribute could be used to store a shapefile, geoJson or GeoPackage, while th...
Guest about 3 years ago in Analytics & Calculations 1 Declined

Properly handle Event Frame edits on Event Frames that are generated by the PI Analysis Service

Users manipulate open event frames that are generated by the PI Analysis Service. The manipulation can be: 1) Write to an attribute on the EF 2) Write an annotation 3) Acknolwedge the EF When these manipulations are being performed the Event Fra...
Guest about 3 years ago in Analytics & Calculations 5 Declined

Poly function should allow number attributes as coefficients

The current Poly function does not support attributes as coefficients, so we need to revert back to using Pow. This makes the Poly function of little additional benefit. We need to be able to use any numeric attribute as input for the Poly coeffi...
Roger Palmen about 3 years ago in Analytics & Calculations 0 No status

I would like the ability to move searches defined on the PSE management tag from computer to computer

I have created numerous searches on the management tab of the PSE, but if changing computers or even sharing the searches between workers you currently have to recreate the searches on each computer. Not sure where these are stored currently, but ...
Guest about 3 years ago in Analytics & Calculations 2 No status

Ability to disable load shedding on Individual analyses

As a PI Admin I would like the ability to disable load shedding on individual analyses. This will ensure that critical analyses do not skip without having to disable load shedding at the service level and potentially impact performance.
Guest about 3 years ago in Analytics & Calculations 2 No status

Performance Counter for Critical, Error, and Warning messages.

In addition to a performance counter for total messages sent into the PI log, it would be very useful to have performance counter to determine which of these messages are Critical, Error, or Warning messages. This way, users can monitor specifical...
Alan Izar about 3 years ago in System Management 0 Declined

export version, configuration and health information for reporting

would like to build report based on the available information. Ex: version installed, configuration of the PI software and their health status.
Guest about 3 years ago in System Management 1 Declined

Suppress [-15011] PIvalue Type is Not Numeric

An option to suppress "[-15011] PIvalue Type is Not Numeric" when there is a non-numeric OOO event (e.g. string or digital value) between the pibufss last compressed event and snapshot event. While these messages are only informational they can qu...
Guest about 3 years ago in System Management 0 Declined

Make message logs easier to export in bulk

Tech support often asks customers for message logs in bulk. The PISDKUtility and SMT are not good for this because they run out of memory if you try to load too many messages. The only way to export the logs is to use the command line pigetmsg uti...
Guest about 3 years ago in System Management 0 Declined