Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach almost 2 years ago in Analytics & Calculations 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest almost 2 years ago in Analytics & Calculations 0 No status

Improve Digital State Set Management

We have hundreds of digital state sets, many of them the same with the exception of their name (e.g., Manual_Auto, ManualAuto, Manual-Auto, Manuel-Auto, ManuelAutomatique; all with states 0: Manual and 1: Auto). In order to clean up these states, ...
Kelsey Bobeck about 2 years ago in System Management 0 No status

Analysis on roll up

We should be able to perform analysis or at least data filter at roll up. e.g. roll up attriubutes A while Attribute B > 5
Guest about 2 years ago in Analytics & Calculations 0 No status

Define time for analysis "evaluate" button to make debugging faster

Currently, the evaluate button can run your evaluation at the current timestamp and the last scheduled time. It would be really helpful to key in a 3rd timestamp to diagnose edge cases. The current workaround involves putting dummy variables in to...
Guest over 2 years ago in Analytics & Calculations 0 No status

Give a warning or more descriptive error message when trying to recalculate when output point has relative time set

Recalculation doesn't work when Relative time is set on the output point. Currently the error given is the one shown in Unable to manually backfill analysis from PI System Explorer: One or more output attributes do not support recalculation. Which...
Guest over 2 years ago in Analytics & Calculations 0 No status

Expose AF Analytics performance statistics for notifications

The new statistics exposed in PI System Explorer in 2022 are helpful, but the next step should be exposing that information in a way that customers could actively monitor it and send proactive alerts. For example, this could include functionality ...
Laurie Dieffenbach over 2 years ago in Analytics & Calculations 0 No status

Add a counter to stale\Bad tags window

In point builder, the number of tags you are working on is displayed in the top right corner. I'd like to suggest the same on the stale tags window. Why? I do systems administration on 380 controls machines across 68 power plants. Of those 380 mac...
Guest almost 3 years ago in System Management 0 No status

Add steam specific heat functions

Steam specific heat is useful in advanced analytics to monitor control valve performance. Isobaric and isochoric specific heat functions are a part of the 1997 IAPWS IF as are the rest of the steam functions already included.
Guest almost 3 years ago in Analytics & Calculations 0 No status

Write arrays to time series pi points

When I have several similar attributes, I'd like to be able to store them as an array of values on a single pi point with the same timestamp. For example: I'm rolling up values for 10 different teams. I currently need 10 rollup analyses, 10 attrib...
Guest almost 3 years ago in Analytics & Calculations 0 No status