Allow dynamic PI Point data references for analysis outputs

Created on behalf of a customer: In order to use fewer attributes in an element, a customer hoped to output analysis results to an attribute with a dynamic PI Point data reference. Unfortunately, with the use of substitution parameters or with str...
Guest about 3 years ago in Analytics & Calculations 3 Declined

Better search criteria in Management tab of PI System Explorer

PI System Explorer Management Tab should have better search criteria. For example, select specific elements in which to rerun an Analysis. Maybe use Element = something OR/AND Element = something else. Or search by element path.
Guest about 3 years ago in Analytics & Calculations 3 No status

Add a column in PI System Directory showing the latest released version of PI Products

It would be helpful to see if our PI system version is up to date and if not, what the latest released version is. This helps us with the upgrade planning.
Guest about 3 years ago in System Management 1 Declined

Individual Collective Members Health (data matches with other nodes)

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/29295-individual-collective-members-health-data-matches-with-other-nodes We would like a way to know if a node in a collective is not receiving the same data as the other nodes....
Guest about 3 years ago in System Management 0 No status

Allow Rollup analysis to output to to an Analysis Data Reference

I would like there to be a way to output the results of a rollup analysis to an Analysis Data Reference, so that I can view a trend without having to write to a PI point. Currently, there is no option to have a rollup analysis that does not write ...
Guest about 3 years ago in Analytics & Calculations 7 Declined

Provide a way to backfill/recalculate analyses from Analysis Template tab in PSE

It is difficult to find all the analyses from template to backfill/recalculate after making changes in Analysis Template.  Currently one has to navigate to the Management plug-in, do some sort of search/filter, then queue the analyses.  ...
Guest about 3 years ago in Analytics & Calculations 1 No status

Analysis - Remove backfilling

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is actually no feature to manually remove a configured backfill on a specific analysis.
Guest about 3 years ago in Analytics & Calculations 3 No status

Include subseconds in output timestamp from variable

Currently we have an analysis with the output timestamp set to be a variable within the analysis. If I map that variable to an output, it includes the subseconds, but the output time for the analysis is truncated to the second. The output time for...
Guest about 3 years ago in Analytics & Calculations 3 No status

PI System Management Tools (SMT) as a web application

Please consider creating a web application like PI Vision Admin, PI Web API Search, PI Manual Logger for Web, and the various integrators, but for PI System Managment Tools (SMT).  I would prefer this to the client-server design now.  It...
Guest about 3 years ago in System Management 5 Declined

Please add product name (eg 2018 SP2) to the version information in PI SMT

You have to translate between software version (eg 3.4.445.688) and the product name (eg 2018 SP2) by searching for a document in support. It would make sense to show the product name in PI SMT alongside the software version
Guest 10 months ago in System Management 0 No status