Add quicker search capability in PI Builder for Data and Asset Server selection.
Add quicker search capability in PI Builder for Data and Asset Server selection.
For managing 50+ PI Data servers in PI Builder, the drop down for selecting the correct server is quite long, requires scrolling, and is easy to accidentally select ...
Refrain from creating PI Points when AF Analytics is doing an expensive calcultion
If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Enable the compatibility of PI Builder with Microsoft 365/O365
With the existing versions, the PI Builder plugin doesn't work with O365 in its full capability. It would be great to have the compatibility setup from PI Builder plugin with MS365.
Guest
almost 2 years ago
in PI Builder
0
No status
Add a performance counter which can measure if Event frame reconciliation is performed correctly
Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Define time for analysis "evaluate" button to make debugging faster
Currently, the evaluate button can run your evaluation at the current timestamp and the last scheduled time. It would be really helpful to key in a 3rd timestamp to diagnose edge cases. The current workaround involves putting dummy variables in to...
Give a warning or more descriptive error message when trying to recalculate when output point has relative time set
Recalculation doesn't work when Relative time is set on the output point. Currently the error given is the one shown in Unable to manually backfill analysis from PI System Explorer: One or more output attributes do not support recalculation. Which...
Expose AF Analytics performance statistics for notifications
The new statistics exposed in PI System Explorer in 2022 are helpful, but the next step should be exposing that information in a way that customers could actively monitor it and send proactive alerts. For example, this could include functionality ...
Steam specific heat is useful in advanced analytics to monitor control valve performance. Isobaric and isochoric specific heat functions are a part of the 1997 IAPWS IF as are the rest of the steam functions already included.