When upgrading PI Analysis service it prompts to select the current server as the one registered for Analyses. If you do not select it, the installation does not pass.
The PI Analysis installation should allow to not change the server registered t...
Currently the Event-Trigger of an analysis works only with data from the snapshot. For my use cases it is necessary to trigger analysis from events in the data archive. This is not possible at the moment. Ideally I would like to configure for each...
Analysis service should be able to use both the string and integer values of attributes with an enumeration set data type.
If an AF attribute is based off an enumeration set, currently an analysis will only evaluate accurately if that attribute is compared to the string portion of the enumeration set. An analysis should be able to use both strings and integers when ev...
It will be great if we have built-in function for correlation coefficient in Asset Analytics, similarly as it is in ProcessBook in xy plots. This would enable us to quickly get estimate on correlation of two variables.
Event frame search in Pi Builder - Add option to define parent element
Add the option to define the parent element in AF for where the event frames are stored. Currently you can only define "Element Name", this could be the same for several elements.
Would also be nice if you could import (and delete) more than 1000...
When retrieving all PI points, there should be an option to also include the Snapshot value. Currently, a user must use other means to retrieve all current values and then merge the two together.
Kelsey Bobeck
about 3 years ago
in PI Builder
3
Completed
Currently if we define multiple start triggers, a child Event Frame is generated when a next star trigger fires.
I would like to 'split' the Event in this case. Thus close the EF and start a new one.
Example use case: I need separate tracking of ...
Preview Results should remember the start and end time
As part of debugging, sometimes I use Preview Results (which is available from right-clicking on an analysis), make some changes, and then use Preview Results again.
It would be useful if PI System Explorer would remember the start and end times ...
Shutdown states should not be written into the analysis output PI Point by default
There should be an easy way to change the default value of the shutdown flag for analysis output PI Points. Right now, the default value is True, which means my analysis will show a "Shutdown" value every time I restart my PI Data Archive. The eas...
As a user of Asset Analytics I would like the UOMs to be consistent and meaningful throughout the calculations that might involve various complex operations so that the written output values are meaningful and with the correct units.