Ability to Manage Global Notification Formats from PI Builder

Currently, there is no button in PI Builder which allows users to bring in Global Notifications Formats. The button would allow users to read in current Formats and then users would be able to Publish edited formats or newly created formats. This ...
Guest about 3 years ago in PI Builder 0 No status

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott over 1 year ago in Analytics & Calculations 1 No status

Put an Asset into Offline Mode which stops related analyses and notifications

Have a way to manually (or automatically via another calculation/analytic) put the status of an asset/equipment into an offline/maintenance mode that has the effect of turning any analyses and notifications for that asset off.
Guest about 3 years ago in Analytics & Calculations 0 No status

Option to use Good Data only in Analyses.

Analyses can suffer from bad calculations due to bad events for a tag, such as system digital state events returned for a numerical tag. Although BadVal() can be implemented to avoid using bad events in these analyses, they add another layer of ...
Guest about 3 years ago in Analytics & Calculations 2 No status

Trigger Rollup Analysis Upon Adding Child Elements

It would be useful to trigger event-triggered rollup analyses upon adding new children. Currently rollup analyses are only triggered when rollup attributes are updated (and not triggered when rollup attributes are added). This would be particularl...
Guest about 3 years ago in Analytics & Calculations 1 No status

Better search criteria in Management tab of PI System Explorer

PI System Explorer Management Tab should have better search criteria. For example, select specific elements in which to rerun an Analysis. Maybe use Element = something OR/AND Element = something else. Or search by element path.
Guest about 3 years ago in Analytics & Calculations 3 No status

Provide a way to backfill/recalculate analyses from Analysis Template tab in PSE

It is difficult to find all the analyses from template to backfill/recalculate after making changes in Analysis Template.  Currently one has to navigate to the Management plug-in, do some sort of search/filter, then queue the analyses.  ...
Guest about 3 years ago in Analytics & Calculations 1 No status

Analysis - Remove backfilling

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is actually no feature to manually remove a configured backfill on a specific analysis.
Guest about 3 years ago in Analytics & Calculations 3 No status

Include subseconds in output timestamp from variable

Currently we have an analysis with the output timestamp set to be a variable within the analysis. If I map that variable to an output, it includes the subseconds, but the output time for the analysis is truncated to the second. The output time for...
Guest about 3 years ago in Analytics & Calculations 3 No status

Generate error when header is misspelled

When editing PI Points, PI Builder does not return any error if one of the headers is wrong or misspelled. Simply, nothing is edited for that header and you  only find out at a later time when looking at the PI point. It would be useful if PI...
Guest about 3 years ago in PI Builder 2 No status