Event frames start trigger on trigger condition change
I would like to be able to define start trigger that fires a e new event frames only if the start condition changes. I mean:
- Start trigger: 'Equip Status' = "ON"
- End trigger: 'Equip rpm' >= 1000
I would like that the event start is triggere...
AF (and PE) expressions currently have AND and OR operators. These work either logically or (if both operands are integer) in a bitwise fashion. There should also be an XOR operator that works the same way, to avoid the messy construct (A AND NOT ...
Analysis Preview Results - Automatically scroll to result row
After generating "Preview Results" (from right mouse click on analysis name on PSE Analysis Templates tab) it would be nice if the upper results table would auto scroll to the related time value when using the trend cursor to click on the results ...
New AF analyses should be automatically backfilled a set time interval upon creation.
There should be an option in PSE to automatically backfill all AF Analyses a set time interval upon creation that can be set once. This would prevent a user from having to manually backfill analyses individually or in a group from the Management p...
Provide a mechanism to export Analyses and Notifications Management searches.
We create the same Analyses and Notifications on multiple servers. This is easy to do using the database export mechanism. But that export does not include Analyses & Notifications Management searches. So, then, it is necessary to recreate the...
Allow BadVal to handle 'No Data' when querying before input tag creation
It is currently not possible to use BadVal and if-then-else logic to handle the 'No Data' system digital state which is returned by a formula data reference or analysis data reference attribute when one of the input tags for the calculation was cr...
It would be nice to have a dependency between Notification in a way that if one Notification is sent other Notifications are not sent.
My use case is this. I have a corporate AF Server that monitors multiple sites. If a site loses power, I would...
Guest
about 3 years ago
in Notifications
0
No status
Include Creation date in event frame properties for Notifications
We see issues where notifications appear to be delivered late but then find the event frame was created at a later time than the actual event because of connectivity issues. Having the creation date of the event frame exposed for a notification wo...
Guest
about 3 years ago
in Notifications
2
No status
As a PI Administrator I need PI Notifications to support custom headers for SOAP web service end points. Some external systems require specific headers and currently it is only possible to customize headers for REST end points. As an example of an...
Guest
about 3 years ago
in Notifications
0
No status