XML or other flat file Delivery channel

Would like to see the ability to create XML or other flat files from PI Notifications as was available in previous versions. We have seen cases where the network that the PI system resides on is locked down to the point that only flat files can be...
Guest about 3 years ago in Notifications 0 No status

Ability to modify SOAP xml format

There are some cases when the sender wants to modify the format of the SOAP xml itself. Currently Notifications service constructs a XML request including all the variables provided by the wsdl.
Guest about 3 years ago in Notifications 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Guest 9 months ago in Analytics & Calculations 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
Guest about 3 years ago in Analytics & Calculations 1 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Guest over 1 year ago in Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Guest over 1 year ago in Analytics & Calculations 0 No status

Recover data from current time moving backwards

Recover data from the current time back rather than start of a data gap to now (current time). The most important thing is to get current data immediately.
Guest about 3 years ago in Analytics & Calculations 1 Declined

Implement default calculations existing in EXCEL.

Implement all the default calculations existing in EXCEL. We need to calculate the IRR (internal rate of return) for every technology: Inside the PI Analysis is not already available the function to calculate the IRR (like for the vb.net, Excel, ...
Guest about 3 years ago in Analytics & Calculations 0 Declined

Easy output attribute mapping search in PSE

No description provided
Guest about 3 years ago in Analytics & Calculations 0 Declined

Better Error Handling and Reporting

On more than one occasion, have missed several days worth of calculations with no indication of a problem. There were errors in the log, however there is nothing monitoring this log. The analytics service was running, but not actually doing anythi...