The ability to utilize three columns as input for interpolation from an AF Lookup Table to determine the result for a fourth column could be beneficial for predictions and analysis.
Currently, only linear and bilinear interpolation is possible fr...
We would like to be able to extract the data reference type (PI Point, None, Formula, Table Lookup, etc.) for an attribute using PI Analysis, similar to the TagType function for PI points.
The TagNum function seems to be the only function that requires a double quote as opposed to single quotes.
Many other TagXXX functions call for single quotes for its attribute or PI Point arguments.
Having more thorough and detailed messages for the Analysis service in the event logs, especially upon startup.
Environment details + Language settings that the Analysis service is using should be mentioned in the startup logs in order to better ...
Allow Analysis timestamp override feature to output milliseconds
When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Remove tag need for Exit() and NoOutput() in analysis
Allow analysis outputting to Analysis Data Reference attributes to make use of the functions Exit() and NoOutput(), instead of requiring only PI Point Data Reference attributes.
Web Service Configuration - Dynamic "Path" for the JSON Body
Allow free-form JSON construction. Maybe not replace the simple JSON guide that is the only entry form now, but free-form would allow the kind of flexibility that would empower the user.
This would allow a single template to be used, rather than...
Guest
about 3 years ago
in Notifications
2
No status
Add the ability to send one email with multiple notifications inside it. User can get overwhelmed if they're getting a lot of SQC notifications at once, would be nice if it was one email with the various notifications listed.
This would work: Ev...
Guest
about 3 years ago
in Notifications
0
No status
To update the last send time of the notification to be based on the configured time in the periodic schedule to resend the notification but not the time of the last notification sent.
Guest
about 3 years ago
in Notifications
0
No status
It would be very useful if an "outage" for PI Notifications could be scheduled. We often start or finish maintenance well outside of work hours, and the flood of PI Notifications can annoy users who are not on site.
Ideally we could set an outage ...
Guest
about 3 years ago
in Notifications
1
No status