Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 311

Delay Real-Time Calculations until backfill is finished.

For recursive Analyses such as below : PrevVal(tagA,'*') + 'TagB' → output : tagA When the PI Analysis Service is down (or the node needs to be restarted), the current calculation needs to be halted until the Backfilling reaches up to the start u...
Guest about 3 years ago in Analytics & Calculations 3 No status

Replace function to be added in AF analysis

It would be interesting to add the Replace function (like the one in StringBuilder) directly in AF Analysis
Gael about 3 years ago in Analytics & Calculations 2 No status

Keep escalating Notification until it is acknowledged, even if no longer active

I would like the option to configure a Notification to continue to be escalated until it has been acknowledged, even after the trigger condition has become false and the Notification is no longer active.
Guest about 3 years ago in Notifications 2 No status

Propagate renames of event frame generation analyses to the notification rules

Currently, if an event frame generation analysis is renamed, all notifications rules that use it will display an error message, saying that the event frame generation analysis might have been renamed or deleted. This message is fine for deletions...
Guest about 3 years ago in Notifications 1 No status

Add reset and hold triggers to SQC analytics

Add the triggers to SQC rules to reset or hold the SQC rule. When monitoring a periodic or batch based process, a user needs to be able to hold the SQC rule or put that rule in a hold state until the process resumes. Without this feature, virtuall...
Guest about 3 years ago in Analytics & Calculations 0 No status

PI Point User Settings in AF Client

The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
Matt Voll about 3 years ago in Analytics & Calculations 7 No status

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott over 1 year ago in Analytics & Calculations 1 No status

Value at End Time in PI Notifications 2.X

It would be nice to have the ability to drag and drop the value at end time of  an attribute in the message format of a Notification. We can do this with the value at start time and the value at send time, but not the value at end time. There...
Guest about 3 years ago in Notifications 1 No status

Notification when message sent to Delivery Endpoint is rejected

When a notification is sent to a delivery endpoint (web service) and the message is rejected, no failure notification is shown within PSE.  In order to track this issue I currently have to sift through the log files looking for exceptions suc...
Guest about 3 years ago in Notifications 2 No status

Provide a means to parse/extract data from the response received by PI Notifications after sending a notification to a web service endpoint

A web service endpoint, for instance ServiceNow, may response with useful information to a notificate, like a ticket number. There should be a way to associate that information with the event frame that triggered the notification.
Guest about 3 years ago in Notifications 2 No status