As a user of Asset Analytics I would like to have more flexibility in including elements in my rollup calculation so that I would not need to build large hierarchies just for the purpose of rollup analyses.
Guest about 3 years ago in Analytics & Calculations 7 Declined

Add reset and hold triggers to SQC analytics

Add the triggers to SQC rules to reset or hold the SQC rule. When monitoring a periodic or batch based process, a user needs to be able to hold the SQC rule or put that rule in a hold state until the process resumes. Without this feature, virtuall...
Guest about 3 years ago in Analytics & Calculations 0 No status

PI Point User Settings in AF Client

The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
Matt Voll about 3 years ago in Analytics & Calculations 7 No status

Receive PI notifications via SMS or WhatsApp delivery channel natively

As an engineer/technician offshore we are rarely in front of a PC or connected to emails. Would prefer to receive SMS or WhatsApp dnotifications without any 3rd party in the middle.
Guest about 3 years ago in Notifications 1 Declined

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott over 1 year ago in Analytics & Calculations 1 No status

Ability to override analysis in a derived template

When i create a derived Element Template, i would like to be able to override an inherited analysis. Now i am severly limited in the re-use of templates due to this limitation. I cannot extend nor exclude functionality in a derived template if thi...
Roger Palmen about 3 years ago in Analytics & Calculations 8 Declined

Analysis - Default Backfill configuration for service startup

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is an urgent need for a DEFAULT per-analysis configuration in case of service startu...
Guest about 3 years ago in Analytics & Calculations 1 Tell us more

Value at End Time in PI Notifications 2.X

It would be nice to have the ability to drag and drop the value at end time of  an attribute in the message format of a Notification. We can do this with the value at start time and the value at send time, but not the value at end time. There...
Guest about 3 years ago in Notifications 1 No status

Notification when message sent to Delivery Endpoint is rejected

When a notification is sent to a delivery endpoint (web service) and the message is rejected, no failure notification is shown within PSE.  In order to track this issue I currently have to sift through the log files looking for exceptions suc...
Guest about 3 years ago in Notifications 2 No status

Provide a means to parse/extract data from the response received by PI Notifications after sending a notification to a web service endpoint

A web service endpoint, for instance ServiceNow, may response with useful information to a notificate, like a ticket number. There should be a way to associate that information with the event frame that triggered the notification.
Guest about 3 years ago in Notifications 2 No status