Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 274

Analysis service should include functionality for limiting an Event Frame to x time after the start trigger.

Timely notification of shutdowns is critical for managing remote unmanned equipment. Control modules outputs may only indicate a fault condition and require and operator to reset locally. Detailed information on the fault condition can be obtained...
Guest about 3 years ago in Event Frames (EF) 0 No status

RTReport Show Event Frames Between Time Frame

The ability to see all event frames for a specified range in a time-based report. Currently, RtReports doesn't have any capability to list existing Event Frames, whether from specific elements or by any criteria and the only Event Frame reporting...
Guest about 3 years ago in Event Frames (EF) 0 No status

PI Interface for Emerson DeltaV Syncade Batch - Allow EF creation for Phase Step and Phase State level

Users would like to have the option to create event frames at the Phase Step or Phase State level using the PI Interface for Emerson DeltaV Syncade Batch. From the Live Library documentation for PI Interface for Emerson DeltaV Syncade Batch (Emer...
Guest about 3 years ago in Event Frames (EF) 0 No status

Download PI Event Frames Interface Manager by itself

It is not possible to download just the PI Event Frames Interface Manager. Request to download PI Event Frames Interface Manager by itself similar to how PI ICU is treated. This would allow users to obtain bug fixes in the PI Event Frames Interfac...
Guest about 3 years ago in Event Frames (EF) 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach almost 2 years ago in Analytics & Calculations 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest almost 2 years ago in Analytics & Calculations 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 2 years ago in Event Frames (EF) 0 No status

Analysis on roll up

We should be able to perform analysis or at least data filter at roll up. e.g. roll up attriubutes A while Attribute B > 5
Guest about 2 years ago in Analytics & Calculations 0 No status

ModifyDate of Event Frames all get modified with security group changes

When someone makes changes to security groups (add, delete, etc) and these groups have global access to event frames in a database, end result is that all event frames get an identical modifydate for that time. We use this modifydate to detect any...
Guest about 2 years ago in Event Frames (EF) 0 No status