Support Key-Pair Authentication In PI AF Table Link

Currently AF Table link only support username and password. With increasing security requirement this is becoming more and more problematic. AF table Link requires unattended connectivity, and updating password every 90 days is not practical. As a...
Guest about 1 year ago in Asset Framework (AF) 1 No status

Disable intellisense ("autofill") feature in PSE

When I’m creating a new EF and I start to type the PiPoint name for the analysis, Pi tries to make my life easier by shortlisting the possible pipoints based of what I am typing. i.e if I type “Temp” a popup will appear with a list of pipoints tha...
Guest over 2 years ago in Asset Framework (AF) 0 No status

Table/Bulk PI Tag Editor for PI System Explorer

Allow you to right-click on an element in the tree and and pop-up a box that searches for all PI Point DR attributes in this element and down the tree from this element with the path, the value, and the configuration string. Supported by a search ...
Martin Bryant over 2 years ago in Asset Framework (AF) 1 No status

Enable PI Point value retrieval methods for Digital PI Points.

We have found great use for the PI Point Value Retrieval Methods available for PI Point attributes. One such use is for displaying downtime percentage for numerous assets on a PI Vision page. The downtime percentage can be calculated for any inter...
Guest almost 3 years ago in Asset Framework (AF) 0 No status

New analysis to perform insert into AFTable

Hello, We have a use case that would benefit from being able to insert into an AFTable from an analysis. This would work in the same way that event frames do, where a trigger condition is meet that causes the row to be inserted. The variables from...
Guest almost 3 years ago in Analytics & Calculations 0 No status

Use the AUDIT filegroup for all CDC tables

When enabling auditing, the default CDC tables are created within the ASSETS filegroup in SQL, while all replication tables are created in the AUDIT filegroup. It would be good if all CDC tables were in the AUDIT filegroup so that all of the audit...
Guest over 1 year ago in Asset Framework (AF) 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Guest over 1 year ago in Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Guest over 1 year ago in Analytics & Calculations 0 No status

Simpler performance analysis service statistics review directly in AF Explorer

Consider implementation performance analysis service statistics in AF Explorer which is now performed in a complicated way by exporting data to Excel, rearranging and viewing in a pivot table. It would also be useful to be able to retrieve that da...
Guest about 3 years ago in Analytics & Calculations 0 No status

Allow EventFrame analysis to link EventFrame to Primary Parent Element

I want to be able to link an EventFrame to the Primary Parent of the Element the EF analysis is defined on. E.g. i use a child element to a Unit to contain the logic to detect and generate downtime events. However, i want the downtime event to li...
Roger Palmen about 3 years ago in Analytics & Calculations 0 No status