Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 86

Apply Time Context to Other DRs in Event Frames

As this post points out, "The PI Point DR allows you to specify whether you want the StartTime or EndTime of the event frame. All other OSIsoft data references - most notably Table Lookup, Formula, StringBuilder - do not give you this option. Thos...
Kelsey Bobeck about 3 years ago in Event Frames (EF) 0 No status

Document publically changes from one version to the next

This applies also to pharma industry, but customer wants exact documentation of what has changed between releases in the underlaying infrastructure. As example after an upgrade, a particular COM technology was no longer used. This could have resul...
Guest about 3 years ago in General 0 No status

Feedback for the "Hardware and PI System Sizing Recommendations Spreadsheet"

Please delete the blank hidden sheet. It's a useless waste of space. On the PI Data Archive sheet, please use named ranges to make your formulas more readable. This will also make it easier for you to catch any mistakes and quickly check if formul...
Guest about 3 years ago in General 1 No status

Add the Unicode support for RDBMS interface

When connecting Redis database via DSN we get error. As interface is ASCII and Redis is Unicode. Please add the unicode support for RDBMS interface.
Guest about 3 years ago in General 1 No status

Allow the PI Interface Configuration Utility to read interface configuration from the secondary in the event that the primary is unavailable

In an HA environment, if the primary Data Archive is unavailable it would be helpful if the Interface Configuration Utility could read the interface configurations from the MDB on the secondary. Additionally, could it be configured so that any cha...
Guest about 3 years ago in General 0 No status

PISDK supporting registry keys for PI servers with names that include non asci characters

Being able to modify the relevant registry key name in HKEY_LOCAL_MACHINE\SOFTWARE\PISystem\PI-SDK\1.0\ServerHandles for server names which have non asci characters. At the moment, when modifying a server with a non ascii name in the registry the ...
Guest about 3 years ago in General 0 No status

Gray out inherited Root Cause Event Frame category

Gray out or remove the inherited Root Cause Event Frame category to avoid having it selected. This will avoid the error " Already Exists"
Guest about 3 years ago in Event Frames (EF) 0 No status

Allow EF Comments Egress via Notifications

In critical operations, managing in-field comments made on production EF's is essential to being world class. Customers need the ability to push out their field comments to surrounding systems and messaging. Most notably production critical event ...
Guest about 3 years ago in Event Frames (EF) 2 No status

Analysis service should include functionality for limiting an Event Frame to x time after the start trigger.

Timely notification of shutdowns is critical for managing remote unmanned equipment. Control modules outputs may only indicate a fault condition and require and operator to reset locally. Detailed information on the fault condition can be obtained...
Guest about 3 years ago in Event Frames (EF) 0 No status

RTReport Show Event Frames Between Time Frame

The ability to see all event frames for a specified range in a time-based report. Currently, RtReports doesn't have any capability to list existing Event Frames, whether from specific elements or by any criteria and the only Event Frame reporting...
Guest about 3 years ago in Event Frames (EF) 0 No status