Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 80

Add the option to set the Event Frame output to be the value of a string attribute with the longest time-span over the Event Frame Duration.

I have an Event Frame string attribute that changes its value over the duration of the Event Frame. I'd like to have the option to set the Event Frame output to be the value of the string attribute with the longest time-span over the Event Frame D...
Guest about 1 year ago in Event Frames (EF) 0 No status

Have Platform Common services for PI use least privilege access on the Azure directory

Some Azure Active Directory (Entra ID) administrators will be hesitant to give the registered application for the AIM Server Directory.Read.All privileges. It should be feasible to give the application lesser privileges on the directory while stil...
Guest over 1 year ago in Security 0 No status

Higher Cache Time for PIEFGEN

A higher Cache time for the PI EFGEN would be great. Currently the limit ist 60 days.
Guest over 1 year ago in Event Frames (EF) 0 No status

Apply Time Context to Other DRs in Event Frames

As this post points out, "The PI Point DR allows you to specify whether you want the StartTime or EndTime of the event frame. All other OSIsoft data references - most notably Table Lookup, Formula, StringBuilder - do not give you this option. Thos...
Kelsey Bobeck about 3 years ago in Event Frames (EF) 0 No status

Remove and disable permissions that do not apply in PI System Explorer's Security Configuration window

In PI System Explorer → File → Database → Edit Security, the "Permissions for" box always lists all permissions that can possibly be set within PI AF, regardless of the selected objects. Instead, only permissions that apply to the selected objects...
Guest about 3 years ago in Security 3 No status

Gray out inherited Root Cause Event Frame category

Gray out or remove the inherited Root Cause Event Frame category to avoid having it selected. This will avoid the error " Already Exists"
Guest about 3 years ago in Event Frames (EF) 0 No status

Allow EF Comments Egress via Notifications

In critical operations, managing in-field comments made on production EF's is essential to being world class. Customers need the ability to push out their field comments to surrounding systems and messaging. Most notably production critical event ...
Guest about 3 years ago in Event Frames (EF) 2 No status

Analysis service should include functionality for limiting an Event Frame to x time after the start trigger.

Timely notification of shutdowns is critical for managing remote unmanned equipment. Control modules outputs may only indicate a fault condition and require and operator to reset locally. Detailed information on the fault condition can be obtained...
Guest about 3 years ago in Event Frames (EF) 0 No status

RTReport Show Event Frames Between Time Frame

The ability to see all event frames for a specified range in a time-based report. Currently, RtReports doesn't have any capability to list existing Event Frames, whether from specific elements or by any criteria and the only Event Frame reporting...
Guest about 3 years ago in Event Frames (EF) 0 No status

PI Interface for Emerson DeltaV Syncade Batch - Allow EF creation for Phase Step and Phase State level

Users would like to have the option to create event frames at the Phase Step or Phase State level using the PI Interface for Emerson DeltaV Syncade Batch. From the Live Library documentation for PI Interface for Emerson DeltaV Syncade Batch (Emer...
Guest about 3 years ago in Event Frames (EF) 0 No status