Event Frame Start and End Timestamp relative to trigger

With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
Guest about 3 years ago in Event Frames (EF) 0 No status

Output Acknowledging Event Frame to PI Tags

AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record. Due to th...
Guest about 3 years ago in Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez about 3 years ago in Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest about 3 years ago in Event Frames (EF) 0 No status

Filter expression '<tagname>'="string" syntax should allow wildcards

Performance Equations syntax for filtering in SMT and Datalink should allow wildcards for strings: For instance, ''="*substring*" interprets the * as a literal character rather than as a wildcard. To achieve the desired filter, it is currently po...
Guest about 3 years ago in System Management 0 Declined

Clearly label or group together obsolete/deprecated/legacy features

PI System Management Tools is littered with legacy features. By grouping them together or clearly labeling them as "legacy" or similar, the user knows which features to use or migrate away from without having to look up each feature individually.
Guest about 3 years ago in System Management 5 Declined

Rearrange the Archive tab in the Point Builder to reflect the relationship between settings

If the Compressing attribute of a PI Point is set to Off, then the compression settings are greyed out, which makes sense because they are irrelevant if Compressing is Off. However, if a PI Point has its Archiving attribute set to Off, nothing is ...
Guest about 3 years ago in System Management 2 Tell us more

Normalized view of the Database Security Table

Currently, the Security column in the Database Security Table uses the following notation for its values (example): piadmin: A(r,w) | piadmins: A(r,w) | PI Readers: A(r) | PIWorld: A(r) This crams multiple PI Identities and access types into a si...
Guest about 3 years ago in System Management 1 Declined

Collect more information about the host operating system environment. For example: is it running Windows Core

As a system administrator or as an upgrade implementation planner, I need to know the operating system environment that is hosting the software. mPI (Managed PI) collects information about the host OS version, whether physical or virtualized, and ...
Guest about 3 years ago in System Management 0 Declined

Use full names and supported ranges in the Point Type dropdown menu in the Point Builder

Consider writing out each point type in full and putting the range of numbers that is supports beside the point type name, making sure the the names are aligned in their own "column" and that the ranges are aligned in their own "column". Examples...
Guest about 3 years ago in System Management 0 Declined