Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 198 of 1341

PI SMT - Archive Editor Improvements

Why is the second server of all selected servers the default selected server for the archive editor? (C# index 1 instead of 0?) If I leave the Tagname empty and press the search button the tag search dialog opens fine. But if I enter some text at...
HolgerJoistOmv about 3 years ago in System Management 0 No status

Increase Box Length for Tagname Field in Archive Editor

The Tagname field visible length should be increased within Archive Editor in System Management Tools. The full tag name is limited and cannot tell what is listed because the name is cut off. (See screenshot and steps listed below.) Steps to repr...
Guest about 3 years ago in System Management 0 No status

Expose connection history information to PI SMT

As PI System administrator, I would like to know the number of clients connection given a time frame. (e.g. * -1 month) Currently, this is only exposed to the pidiag command line utility. It would help me as a pi system admin to see it within a us...
Guest about 3 years ago in System Management 0 No status

Replace "timeout parameters" with "tuning parameters" in the description of the PITUNING Database Security table

In PI System Management Tools, under the Database Security plugin, the description of the PITUNING table is: "Controls access to Timeout parameters and the Firewall" "Timeout parameters" is the old name for "tuning parameters", I'm guessing from ...
Guest about 3 years ago in System Management 0 No status

Make the tuning parameter Base_AllowSIDLookupFailureForMapping visible by default

When this tuning parameter is enabled, it prevents a PI Collective from being flagged as out-of-sync when some of the PI Collective members can resolve the SID of a PI Mapping and others cannot. However, by default, this tuning parameter is hidden...
Guest about 3 years ago in System Management 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 2 years ago in Event Frames (EF) 0 No status

Improve Digital State Set Management

We have hundreds of digital state sets, many of them the same with the exception of their name (e.g., Manual_Auto, ManualAuto, Manual-Auto, Manuel-Auto, ManuelAutomatique; all with states 0: Manual and 1: Auto). In order to clean up these states, ...
Kelsey Bobeck about 2 years ago in System Management 0 No status

ModifyDate of Event Frames all get modified with security group changes

When someone makes changes to security groups (add, delete, etc) and these groups have global access to event frames in a database, end result is that all event frames get an identical modifydate for that time. We use this modifydate to detect any...
Guest about 2 years ago in Event Frames (EF) 0 No status

Option to specify the a EF Snapshot value with a specific Offset

We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
Guest over 2 years ago in Event Frames (EF) 0 No status