Download PI Event Frames Interface Manager by itself

It is not possible to download just the PI Event Frames Interface Manager. Request to download PI Event Frames Interface Manager by itself similar to how PI ICU is treated. This would allow users to obtain bug fixes in the PI Event Frames Interfac...
Guest about 3 years ago in Event Frames (EF) 0 No status

Easy selection of PI Archives to Backup

Currently, if we want to do a backup of an archive in SMT, we have to tick it. But the customer may has like 500 archives and wants to copy 100 of them. There is currently no friendly-user way to select multiple archives (without unregister them) ...
Guest about 3 years ago in System Management 0 No status

Add ability to honor archive list file locations when adding new server to PI HA Collective

When adding a new server to a PI HA Collective, all archive files selected to be included in the initialization are copied and registered with the new server in one defined location in collective manager.  This can create more manual work for...
Guest about 3 years ago in System Management 1 No status

PI SMT - Archive Editor Improvements

Why is the second server of all selected servers the default selected server for the archive editor? (C# index 1 instead of 0?) If I leave the Tagname empty and press the search button the tag search dialog opens fine. But if I enter some text at...
HolgerJoistOmv about 3 years ago in System Management 0 No status

Increase Box Length for Tagname Field in Archive Editor

The Tagname field visible length should be increased within Archive Editor in System Management Tools. The full tag name is limited and cannot tell what is listed because the name is cut off. (See screenshot and steps listed below.) Steps to repr...
Guest about 3 years ago in System Management 0 No status

Expose connection history information to PI SMT

As PI System administrator, I would like to know the number of clients connection given a time frame. (e.g. * -1 month) Currently, this is only exposed to the pidiag command line utility. It would help me as a pi system admin to see it within a us...
Guest about 3 years ago in System Management 0 No status

Replace "timeout parameters" with "tuning parameters" in the description of the PITUNING Database Security table

In PI System Management Tools, under the Database Security plugin, the description of the PITUNING table is: "Controls access to Timeout parameters and the Firewall" "Timeout parameters" is the old name for "tuning parameters", I'm guessing from ...
Guest about 3 years ago in System Management 0 No status

Make the tuning parameter Base_AllowSIDLookupFailureForMapping visible by default

When this tuning parameter is enabled, it prevents a PI Collective from being flagged as out-of-sync when some of the PI Collective members can resolve the SID of a PI Mapping and others cannot. However, by default, this tuning parameter is hidden...
Guest about 3 years ago in System Management 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.