Download PI Event Frames Interface Manager by itself

It is not possible to download just the PI Event Frames Interface Manager. Request to download PI Event Frames Interface Manager by itself similar to how PI ICU is treated. This would allow users to obtain bug fixes in the PI Event Frames Interfac...
Guest about 3 years ago in Event Frames (EF) 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 2 years ago in Event Frames (EF) 0 No status

ModifyDate of Event Frames all get modified with security group changes

When someone makes changes to security groups (add, delete, etc) and these groups have global access to event frames in a database, end result is that all event frames get an identical modifydate for that time. We use this modifydate to detect any...
Guest about 2 years ago in Event Frames (EF) 0 No status

Reformat 2023 help/doc files so text not scrolling off the right hand side of page.

An example of the issue can be found in the 2023 Pi System Explorer help/user doc when searching for "Impact score". The text box goes past the edge of the page and you don't know if you are missing something important.
Guest over 2 years ago in Help / Documentation / Videos 0 No status

Option to specify the a EF Snapshot value with a specific Offset

We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
Guest over 2 years ago in Event Frames (EF) 0 No status

More filtering options for AFDiag /DelEF command

It would be nice to have more filtering parameter options for the "AFDiag /DelEF" command such as Duration, etc using the command prompt. Currently, we can only filter on Template and Database Name for event frames. I've needed to bulk delete even...
Guest about 3 years ago in Event Frames (EF) 0 No status

Doubt

I have a question. I am adding a PI points to Attribute templates and Default values do not change. Why that is happening? Thank you
Guest about 3 years ago in Help / Documentation / Videos 0 No status

Support for Product & Campaign Contexts

Better support contexts beyond Batch ID and Product. For example, Campaign, Order #, etc. that business users are more familiar with.
Guest about 3 years ago in Event Frames (EF) 0 No status

Select the EF Template in EF Generation Analyses created from AF Element Templates

Any AF Analysis that creates Event Frames needs to have an Event Frame template assigned to it, which is used to create the Event Frame. The Security settings of the Event Frame template are used to assign the Security settings of all Event Frames...
Christoph Rose about 3 years ago in Event Frames (EF) 0 No status