Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 300

To have a ‘second’ Reason column available

It would be great to use Event Frames to classify and afterwards be able to do Equipment Downtime root cause analysis. We’re using Reason codes on the predefined field, however it would be great to have a second available Code Editors than “Reason...
Guest about 3 years ago in Event Frames (EF) 1 No status

Substitution parameter from root

As an AF administrator, I want to configure templates with Point Creation using Substitution Parameters that can retrieve names and values from an element relative to the root element and working it's way down to the element wanted. A way for this...
Guest about 3 years ago in Asset Framework (AF) 4 No status

Option to write Default Value to PI tags created through AF Templates

When creating PI points through AF Templates, there should be an option to "Write Default Value after Point Creation", or some other way to initialize the value of an automatically created PI tag. Right now, there is no way to replace the Pt Cre...
Guest about 3 years ago in Asset Framework (AF) 3 No status

Convert should allow to override UOM

The introduction of the property "Delta UOM", made clear that when an incorrect UOM is set for an analysis result, there is no way (except casting to text and back to number) to change the UOM to a UOM of a different class. We need the convert fun...
Roger Palmen about 3 years ago in Asset Framework (AF) 2 No status

Allow programmatic access to AF audit trail for report generation

As a PI admin I would like to be able to generate reports based on the AF audit trail.  Currently the audit trail can be accessed manually using the audit trail utility tool and manually output a file, though I would like to be able to query ...
Guest about 3 years ago in Asset Framework (AF) 2 No status

Make AFDiag timeout based on AFService.exe.config settings

Make AFDiag timeout parameter based on AFService.exe.config settings instead of being hard coded.
Guest about 3 years ago in Asset Framework (AF) 2 No status

Customized PI System Explorer view

Currently PI System Explorer views lots of stuff that is not used by most users (ports, models etc.) also, there are some things that may depend on decisions of particular client - for example, I don't want my users to use Formulas. I suggest to p...
Guest about 3 years ago in Asset Framework (AF) 2 No status

Include AFDiag /AddIdentity functionality to PSE

Adding an identity to an established large system can cause a flood of change records, leading to performance issues. The AFDiag /AddIdentity feature will bypass this issue, but it would be more convenient to have this functionality included in PSE.
Guest about 3 years ago in Asset Framework (AF) 2 No status

Effective Access tab in PSE should show Owner Identity

This enhancement would be resolving a rare problem, as the Owner Identity is not granted rights to any Items in AF by default. It would be due to the security scheme configured in AF, which the responsible AF Administrator should be aware of. The ...
Guest about 1 year ago in Asset Framework (AF) 0 No status

Dynamic EF root cause duration

To avoid creating several templates, suggested adding the possibility to choose the duration In the Event Frame-->Advanced Event Frame Settings-->Generate child root cause event frame before parent event frame starts, to be different for eac...
Guest almost 3 years ago in Event Frames (EF) 0 No status