Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 300

Fix PI Builder publication of AF Analyses with annotations

When publishing an AF Analysis via PI Builder, if the AnalysisRuleConfigString has annotations (preceded by "//"), then the entire portion of the ConfigString that follows is treated as a comment. There needs to be a way to specify an end-of-comme...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Support for Product & Campaign Contexts

Better support contexts beyond Batch ID and Product. For example, Campaign, Order #, etc. that business users are more familiar with.
Guest about 3 years ago in Event Frames (EF) 0 No status

Select the EF Template in EF Generation Analyses created from AF Element Templates

Any AF Analysis that creates Event Frames needs to have an Event Frame template assigned to it, which is used to create the Event Frame. The Security settings of the Event Frame template are used to assign the Security settings of all Event Frames...
Christoph Rose about 3 years ago in Event Frames (EF) 0 No status

Display multiple attributes on same graph for Event Frames

We would like to be able to display multiple attributes on the same graph for Event Frames. For example: For a given event frame, I am collecting data associated with ph control. Therefore when looking at graph for a certain event frame I would li...
Guest about 3 years ago in Event Frames (EF) 0 No status

Display path of element in the PSE

As a user, I would like to be able to easily see the full path of an element in the General tab, and be able to copy this path to my clipboard.
Guest about 3 years ago in Asset Framework (AF) 1 No status

Add a space before "Template" in the default element template name after using "Convert To Template"

Currently, if you convert an element to a template, the default name of the template is of the form "[Element Name]Template". Please consider changing this to "[Element Name] Template" to increase readability and make the name more consistent with...
Guest about 3 years ago in Asset Framework (AF) 0 No status

If an attribute template changes type from A to B and uses A's default value, then use B's default value

If an attribute template is of data type A and its default value is the default value of data type A, then if we change the attribute template's data type to B, then the attribute template's default value should become the default value of B. For...
Guest about 3 years ago in Asset Framework (AF) 1 No status

If the reference UOM of a UOM changes, relabel the sample conversion immediately

If you add or edit a UOM and change the reference UOM when the method type is "Simple", the sample conversion will not reflect this change unless the factor or the offset is edited. Instead, the change in the reference UOM should be reflected imm...
Guest about 3 years ago in Asset Framework (AF) 1 No status

Tool for SQL Security and Consistency Check for the PI AF Server

It is difficult to manage the AF security complexity and ensure proper authorizations so that there are no security holes.  I would like a built-in tool that can go through and check various aspects of AF/PIFD security and integrity and gener...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Allow the boxes in PI System Explorer's Security Configuration window to be vertically resized

In PI System Explorer → File → Database → Edit Security, the border under the "Items to Configure" box and above "Identities" and "Permissions for" should be adjustable. This would allow "Items to Configure" to grow and the other 2 boxes to shrink...
Guest about 3 years ago in Asset Framework (AF) 0 No status