Update 'Modified date' of an event frame when an attribute is filled in manually (for example with reason code)
At this point, only the modified date of an event frame is updated when the event frame is created or when a backfill or recapture is performed. For transferring data to a data lake or warehouse, it would be very useful to see which event frames c...
Ability to find the EFGEN configuration server name and interface ID for Event frames
It would be great if we can know from which machine EFGEN interface are configured and the corresponding EFGEN interface Id for a particular event, so it will be easy to troubleshoot the issues occurring in event frame generation.
I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest
about 3 years ago
in Data Archive
1
No status
Supporting Decimal type for PI tag in PI Data Archive
For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li
about 2 years ago
in Data Archive
0
No status
Association of Multiple Tags That Represent Same Measurement
As a PI admin, I would like to associate mutiple tags together that represent the same measurement at different time periods SO THAT users see one set of data together instead of the old data in the old tag and the new data in the new tag after DC...
Guest
about 3 years ago
in Data Archive
0
Declined
PI SMT: some plugins missing features for future data
Certain plugins in PI SMT do not have features to support future data
1. Snapshot and Archive Statistics (is available only through piartool)
2. Current Data does not subscribe to timeseries in Update Manager
3. Stale and Bad tags
Guest
about 3 years ago
in Data Archive
0
Declined
Store PI Data Archive information in an SQL Server database
Most of the PI Data Archive information that is accessible from PI System Management tools is perfect for a relational database: PI Identities, PI Mappings, PI Point attributes, PI Message Logs, etc.
Moving all of this to an SQL Server database w...
Guest
about 3 years ago
in Data Archive
1
Declined
I see too often customers struggling to find the right exception and compression settings. When exception/compression are not well defined, they end up having too many values or missing values, what causes a lot of problems when the affected tag i...
Guest
about 3 years ago
in Data Archive
0
Declined