Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

add-on for dataquality

Data scientists are 70% of their time busy with cleaning data. In the pi system, we can se lo and hi limits, but dataquality is more than that. It's also about consistent and continuous datarate, strange sensor signals,...Within Pi, this is still ...
Guest over 1 year ago in Data Archive 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 2 years ago in Event Frames (EF) 0 No status

ModifyDate of Event Frames all get modified with security group changes

When someone makes changes to security groups (add, delete, etc) and these groups have global access to event frames in a database, end result is that all event frames get an identical modifydate for that time. We use this modifydate to detect any...
Guest about 2 years ago in Event Frames (EF) 0 No status

How to fix errors that prevent users from creating new PI Points, other than restarting the services.

Occasionally an error that prevent users from creating new PI Points occurs. In this case, I would like you to prepare other error resolution methods, because restarting the services will make the PI system temporarily unavailable.
Guest over 2 years ago in Data Archive 0 No status

Create "aliases" of a pipoint using attributes

the idea is to have the possibility to assign a single tag more than one name, providing it a list of aliases in case of need. many tags in pi have names that were fine at the time they were created but after some years their name should be "chang...
Guest over 2 years ago in Data Archive 0 No status

online managed switch of primary member in a collective

Hi, this idea is to allow an automated command in the collective manager in order to perform in a single command downgrade the current primary server to just "secondary" role without rebuilding "all" the DA server, and at the same time to promote ...
Guest over 2 years ago in Data Archive 0 No status

Option to specify the a EF Snapshot value with a specific Offset

We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
Guest over 2 years ago in Event Frames (EF) 0 No status

More filtering options for AFDiag /DelEF command

It would be nice to have more filtering parameter options for the "AFDiag /DelEF" command such as Duration, etc using the command prompt. Currently, we can only filter on Template and Database Name for event frames. I've needed to bulk delete even...
Guest about 3 years ago in Event Frames (EF) 0 No status

Provide the user ability to select Event Frame templates during the Batch to Event Frames Migration

During the Batch to Event Frames Migration, all migrated Event Frames are created with 'Migrated' templates (i.e. PIBatchMigrated, PIUnitBatchMigrated, etc.). I would like the ability to pick and choose what templates migrated Event Frames are cre...