Keeping old events that have been manually worked on in case of Recalculation/Backfill

Case 1. There are some EFs that should be acknowledged and commented by equipment owners. In Pharma World, these comments qualify as GxP and shall not be deleted. Whereas Event Frames generated by analysis can sometimes due to data coming late or ...
Guest about 3 years ago in Event Frames (EF) 1 No status

End first child event frame when StartTrigger condition no longer is fulfilled

Currently child event frames are only created when the following applies: + There's an End Trigger + There's a second Start Trigger that takes over Unlike later child event frames, the first one will not end simply because its own Start Trigger c...
Guest about 3 years ago in Event Frames (EF) 1 No status

Option to write EF template attribute result back into a PI-tag

Creating a possibility to populate PI-tag's based on the Events. These PI-tag's can be used in reports/displays. Generating batch, daily, hourly, shift and other "event" driven values and store them in a specific PI-tags would very easy and may re...
Guest about 3 years ago in Event Frames (EF) 1 No status

Add the option to set the Event Frame output to be the value of a string attribute with the longest time-span over the Event Frame Duration.

I have an Event Frame string attribute that changes its value over the duration of the Event Frame. I'd like to have the option to set the Event Frame output to be the value of the string attribute with the longest time-span over the Event Frame D...
Guest about 1 year ago in Event Frames (EF) 0 No status

To bring back Archive Activity Grid feature

To bring back Archive activity grid which brings many insights for the administrators for archive health monitoring. My suggestion is to maybe enhance it and provide a UI base functionality, similar to PI AuditViewer.
Guest about 1 year ago in Data Archive 0 No status

Export Multiple Audit Logs into one XML/TXT File

The pidiag -xa utility doesn't support selecting a folder location and exporting the contents to a single XML/TXT file. This would be very helpful for bulk auditing actions.
Guest over 2 years ago in Data Archive 1 No status

Ability to reprocess individual points to handle digital set changes

Current functionality: When changing a point from digital set A to digital set B, all events going forward will use digital set B. If you do not reprocess the archives, the events that were archived before the digital state was changed remain asso...
Guest over 1 year ago in Data Archive 0 No status

Higher Cache Time for PIEFGEN

A higher Cache time for the PI EFGEN would be great. Currently the limit ist 60 days.
Guest over 1 year ago in Event Frames (EF) 0 No status

Backup directly to AWS S3 bucket

We've successfully migrated our entire PI System into the AWS environment. Therefore it would be very nice if the pibackup.bat script would be able to directly backup to an S3 bucket.
Guest over 1 year ago in Data Archive 1 No status

Store a timestamp of when an event enters the archive database

We have a use case that could be solved very easy if we have had this as a column in the data archive. Use case: We have made PI data availible through an own made API to our clients. They use this API to fetch data from our database and into thei...
Ole Dybsjord Skarsvag about 3 years ago in Data Archive 0 No status