How to fix errors that prevent users from creating new PI Points, other than restarting the services.
Occasionally an error that prevent users from creating new PI Points occurs. In this case, I would like you to prepare other error resolution methods, because restarting the services will make the PI system temporarily unavailable.
Guest
over 2 years ago
in Data Archive
0
No status
the idea is to have the possibility to assign a single tag more than one name, providing it a list of aliases in case of need. many tags in pi have names that were fine at the time they were created but after some years their name should be "chang...
Guest
over 2 years ago
in Data Archive
0
No status
online managed switch of primary member in a collective
Hi, this idea is to allow an automated command in the collective manager in order to perform in a single command downgrade the current primary server to just "secondary" role without rebuilding "all" the DA server, and at the same time to promote ...
Guest
over 2 years ago
in Data Archive
0
No status
Option to specify the a EF Snapshot value with a specific Offset
We would like to configure a snapshot value in a EF for e.g. +10min and +20min after the EF start. Currently this is not possible with the EF Data value retrivial methods Refered Case is #01074855
It would be nice to have more filtering parameter options for the "AFDiag /DelEF" command such as Duration, etc using the command prompt. Currently, we can only filter on Template and Database Name for event frames. I've needed to bulk delete even...
The disadvantage of fixed archives is that they cannot grow or shrink. The disadvantage of dynamic archives is that they can potentially grow too much. Merging of small archives and splitting of large archives must be done manually.
To solve this...
Guest
about 3 years ago
in Data Archive
0
Declined
Ability to convert historical tags to future data tags
As a production supervisor, I would like to be able to convert historical data tags to future data tags so that I can more efficiently transition my production target tags from being something that I have to update every day, to something that I c...
Guest
about 3 years ago
in Data Archive
0
Declined
Make a point class similar to "base", but without zero, span, or typical value
Most of the time, zero, span, and typical value are unused, cause confusion, and/or lead to easy but costly mistakes.
Typical value is probably the most useless PI Point attribute. It doesn't affect the PI system. It is just there for the user's ...
Guest
about 3 years ago
in Data Archive
0
Declined
Write a description for the PI Data Archive services
When you open the Services program (services.msc), none of the PI Data Archive services have a description. Please provide descriptions for these. The specific services are: PI Archive Subsystem PI Backup Subsystem PI Base Subsystem PI Buffer Subs...
Guest
about 3 years ago
in Data Archive
0
Declined
Provide the user ability to select Event Frame templates during the Batch to Event Frames Migration
During the Batch to Event Frames Migration, all migrated Event Frames are created with 'Migrated' templates (i.e. PIBatchMigrated, PIUnitBatchMigrated, etc.). I would like the ability to pick and choose what templates migrated Event Frames are cre...
Guest
about 3 years ago
in Data Archive
0
No status