In the DA collective there is a function called "Failback". The function is described as:
<< When the collective member which the client application was connected to becomes unavailable, the client connection starts monitoring when the memb...
Guest
about 3 years ago
in Data Archive
0
No status
The AF XML Import/Export is described by OSIsoft as a tool for backing up and restoring an AF database to either the same server or a different server. However, one object relationship that is not included in the XML file is an Event Frame's refer...
It would be great to use Event Frames to classify and afterwards be able to do Equipment Downtime root cause analysis. We’re using Reason codes on the predefined field, however it would be great to have a second available Code Editors than “Reason...
To avoid creating several templates, suggested adding the possibility to choose the duration In the Event Frame-->Advanced Event Frame Settings-->Generate child root cause event frame before parent event frame starts, to be different for eac...
Can buffer subsystem be enhanced to manage value deletions from tags? We have a collective and utilize buffering to send data to both collective members however we have to jump through hoops to delete data from both collective members. It would be...
Guest
about 3 years ago
in Data Archive
1
No status
smarter calculation of PI Backup required free space
When backfilling tags from AF its very easy to update many archives. I would like the backup script to only require free space for archives that don't exist in the target folder. We have periodic incremental backup failures do to a lack of free di...
Guest
about 3 years ago
in Data Archive
3
No status
Replace the batch (.bat) scripts in the %PISERVER% folder with PowerShell (.ps1) scripts
This replacement is appropriate for several reasons: PowerShell is easier to read and is a more powerful language than the batch language. Batch scripts are best used in Windows, whereas PowerShell is cross-platform. This replacement will support ...
Guest
about 3 years ago
in Data Archive
1
No status
Optimize and compress non-primary historic archive files
Currently, the same file format is used for primary and non-primary historic archive files. This does not make much sense since the two types are used very differently. For the primary archive: Write operations should be fast since it is collectin...
Guest
about 3 years ago
in Data Archive
4
No status
Users should be able to define display digits on Archive editor
Currently the Archive editor doesn't allow users to define how many digits should be shown for the data values and it does not follow the DisplayDigits tag attribute setting. Users should be able to define how many digits to be shown.
Guest
over 2 years ago
in Data Archive
0
No status
For the moment some Archive corruption are not detected automatically by PI DA. For example error -15000 due to archive corruption. Please enhanced the archive corruption detection because we have more and more long history and it can become diffi...
Guest
over 2 years ago
in Data Archive
0
No status