Showing 139

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez about 3 years ago in Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest about 3 years ago in Event Frames (EF) 0 No status

Provide a MUI Kit for the Data Archive / SMT

Provide a MUI Kit for the Data Archive / SMT
David Scott almost 2 years ago in Data Archive 0 No status

Update 'Modified date' of an event frame when an attribute is filled in manually (for example with reason code)

At this point, only the modified date of an event frame is updated when the event frame is created or when a backfill or recapture is performed. For transferring data to a data lake or warehouse, it would be very useful to see which event frames c...
Guest 12 months ago in Event Frames (EF) 0 No status

Ability to find the EFGEN configuration server name and interface ID for Event frames

It would be great if we can know from which machine EFGEN interface are configured and the corresponding EFGEN interface Id for a particular event, so it will be easy to troubleshoot the issues occurring in event frame generation.
Guest 12 months ago in Event Frames (EF) 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Guest about 3 years ago in Data Archive 1 No status

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li about 2 years ago in Data Archive 0 No status

Auto Archive Management - Shift vs. Delete

Currently, there are two methods to 'shift' archives: 1. "Archive_AutoArchiveFileRoot" set to blank 2. "Archive_OverwriteDataOnAutoShiftFailure" enabled Neither method shifts to dynamic archives. We have three sites that merged PI servers, thus ha...
Pete Long about 3 years ago in Data Archive 1 No status

Event Frames Scalability - For Customer Advisory Lab Scenarios

#of assets (in this specific scenario): 500-1000 EF Count: Generation rate of 25,000/day peak, would like to historize for 1+y = 9,000,000 events+ Attributes: 5-10 attributes/event (static or PI Point) Flat Hierarchy Queries: EF are alarms or ...
Guest about 3 years ago in Event Frames (EF) 0 No status

Store event frame start and end time as DateTime to allow sub-millisecond duration event frames

Because event frame start and end time are stored as a bigint datatype in PIFD.dbo.AFEventFrame, the precision only seems to be to the nearest millisecond. This is a problem for sub-millisecond event frames. Why aren't event frame start and end ti...