When generating Event Frames it would be useful to automatically remove the Event Frame, either when no longer active or in combination with no longer active and acknowledged, or other conditions.
An example use case would be for PI Notifications...
Parametrize the "True for x minutes" parameter in event frame analysis
It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Add the option to delete all event frames that reference an element when the element is deleted
When deleting an element using PI System Explorer, there should be an option to delete all event frames that reference the element. Currently when deleting an element, the delete option "Delete this object and all references to it" does not delete...
Event Frame Re-capture/Backfill Option to Save Annotations/Reasons
When a backfill or "recapture events" option is selected for Event Frames, give the user an option to "Save Annotations" for that specific event frame. Right now, we use Event Frames to copy in Reason Codes and Comments (that are logged as annotat...
Additional documentation and examples to reference non-primary referenced Elements on Event Frames Templates
Some users asked for an enhancement of the documentation/ guide videos regarding syntax for referencing a non-primary element on a PI Point attribute from Event frame templates. The OSIsoft live guide does not provide enough information and/or exa...
Outputs at close available for all generation modes
‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'.
If y...
PI EFGen interface : allow configuration of events without OS-admin rights
PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
You should be able to urge EFs using more complex search criterias' than the ones provide in the latest PI Server 2018 SP3 (StartTime, EndTIme, EF Template).
Most important criteria would be EF categories, but also some honorable mentions:
1. EF ...
I would like to see an option on an event frame generation analysis, probably under advanced event frame settings, that enables automatic event frame name reevaluation at the end time of the generated event frame. Right now I have event frame gene...