Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Event Frames (EF)

Showing 56

Higher Cache Time for PIEFGEN

A higher Cache time for the PI EFGEN would be great. Currently the limit ist 60 days.
Guest over 1 year ago in Event Frames (EF) 0 No status

Apply Time Context to Other DRs in Event Frames

As this post points out, "The PI Point DR allows you to specify whether you want the StartTime or EndTime of the event frame. All other OSIsoft data references - most notably Table Lookup, Formula, StringBuilder - do not give you this option. Thos...
Kelsey Bobeck almost 3 years ago in Event Frames (EF) 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Guest over 1 year ago in Event Frames (EF) 0 No status

Gray out inherited Root Cause Event Frame category

Gray out or remove the inherited Root Cause Event Frame category to avoid having it selected. This will avoid the error " Already Exists"
Guest about 3 years ago in Event Frames (EF) 0 No status

Allow EF Comments Egress via Notifications

In critical operations, managing in-field comments made on production EF's is essential to being world class. Customers need the ability to push out their field comments to surrounding systems and messaging. Most notably production critical event ...
Guest about 3 years ago in Event Frames (EF) 2 No status

Analysis service should include functionality for limiting an Event Frame to x time after the start trigger.

Timely notification of shutdowns is critical for managing remote unmanned equipment. Control modules outputs may only indicate a fault condition and require and operator to reset locally. Detailed information on the fault condition can be obtained...
Guest about 3 years ago in Event Frames (EF) 0 No status

RTReport Show Event Frames Between Time Frame

The ability to see all event frames for a specified range in a time-based report. Currently, RtReports doesn't have any capability to list existing Event Frames, whether from specific elements or by any criteria and the only Event Frame reporting...
Guest about 3 years ago in Event Frames (EF) 0 No status

PI Interface for Emerson DeltaV Syncade Batch - Allow EF creation for Phase Step and Phase State level

Users would like to have the option to create event frames at the Phase Step or Phase State level using the PI Interface for Emerson DeltaV Syncade Batch. From the Live Library documentation for PI Interface for Emerson DeltaV Syncade Batch (Emer...
Guest about 3 years ago in Event Frames (EF) 0 No status

Download PI Event Frames Interface Manager by itself

It is not possible to download just the PI Event Frames Interface Manager. Request to download PI Event Frames Interface Manager by itself similar to how PI ICU is treated. This would allow users to obtain bug fixes in the PI Event Frames Interfac...
Guest about 3 years ago in Event Frames (EF) 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest almost 2 years ago in Event Frames (EF) 0 No status