Asset Framework (AF)

Showing 238

Ability to move an AF element within the hierarchy in PSE by right-clicking on the element

When moving an AF element within the hierarchy in PSE using the "Shift key + Drag and Drop" approach, it can cause to create an Element reference if the release of the "Shift key" is done before dropping the element. Having the option of right-cl...
Guest almost 3 years ago in Asset Framework (AF) 0 No status

Validate Dynamic Endpoints config for notifications with new Attribute Data Reference Type

Dynamic endpoints with comma separated email addresses are the preferred method for addressing notification recipients. They allow all recipients to see which other recipients have received the notification. The downside is any syntax error (e.g. ...
Guest 11 months ago in Asset Framework (AF) 0 No status

backfilling start date error

I have one specific complaint but when I’m creating/testing a new event frame it is the worst. When backfilling a single analysis, the start time and end time boxes will throw an error and not allow the you to start the backfill if at any time the...
Guest 4 months ago in Asset Framework (AF) 0 No status

Harmonize Attribute Editor and Attribute Template Editor

Currently Attribute Template Editor and Attribute Editor behave different regarding visualisation of templates when using derived templates. Attribute Template Editor shows the attributes of the base template only if Group By Template is checked....
Guest almost 3 years ago in Asset Framework (AF) 5 No status

Substitution Parameters for PI Point Exdesc

I would like to have an out of the box way for an attribute to display a pipoint exdesc. One thought would be able to have a substitution parameter that would point at the pipoints exdesc.
Guest almost 3 years ago in Asset Framework (AF) 0 No status

Allow internal AF Tables to be linked from one AF Database to another

In some scenarios, creating a linked table to an internal AF table is more appropriate than linking to an external table. For example, an internal AF table which contains a list of assets and their associated tag name may be applicable to multiple...
Guest almost 3 years ago in Asset Framework (AF) 0 No status

Effective Access tab in PSE should show Owner Identity

This enhancement would be resolving a rare problem, as the Owner Identity is not granted rights to any Items in AF by default. It would be due to the security scheme configured in AF, which the responsible AF Administrator should be aware of. The ...
Guest 8 months ago in Asset Framework (AF) 0 No status

Support "category" for the name substitution parameter in AF template

Use category of an attribute for the name substitution parameter of the PI point data reference
Guest almost 3 years ago in Asset Framework (AF) 3 No status

AF "instrumenttag property request

Users would like to be able to pull in the instrumenttag of a PI point into an attribute that is referencing it.  This isn't currently possible because the AF server and any attribute aren’t aware of most properties of the PI point itself, so...
Guest almost 3 years ago in Asset Framework (AF) 1 No status

Automatic re-connection to AF database after network interruption

Avoid having to manually reconnect to the AF database in PSE whenever a client computer returns from standby after the network connection has returned. Other PI client tools such as SMT are able to automatically re-establish connection under these...
Guest almost 3 years ago in Asset Framework (AF) 0 No status