Showing 123 of 1323

Reprocess fixed archives to dynamic or visa versa

Currently, PI SMT will only allow archives to be reprocessed according to it's original type. User would like to be able to choose whether to reprocess the archives from fixed to dynamic or vice versa.
Guest almost 3 years ago in Data Archive 1 Declined

PI Archive ability to recover from drive disconnect

With everyone having virtual servers these days the host VM and SAN storage are on separate devices. When the storage device is unavailable or disconnected even briefly, the PI Archive process errors and gets DISABLED and can ONLY be restarted by ...
Guest almost 3 years ago in Data Archive 1 No status

PI Data Archive - import tags and merge historic archives together

As a customer who is moving their PI Data Archive historic data to a Centralized IT Facility, hosting another PI Data Archive, and that would like to import tags and historic data from another PI Data Archive, it would be great to have a functiona...
Guest almost 3 years ago in Data Archive 0 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Guest 10 months ago in Data Archive 0 No status

Dedicate/reserve threads for PI server management.

In the event of all the threads being consumed on a PI server a PI admin is unable to manage a PI server remotely. They must remote into the server and manage it from there. However, even from the server there are times where simple tasks like ope...
Guest over 1 year ago in Data Archive 0 No status

Support storing data quality

As a user I want to be able to collect, store and analyze quality information associated with real-time events and assets. This feature will allow the user to determine the trustworthiness of the data when decisions are made. Note: This was previ...
Guest almost 3 years ago in Data Archive 0 Declined

PI Data Archive: Improve piarchss performance

PI Archive Subsystem should be able to use operating memory more efficiently. For example by loading as many non-primary archives into its process memory as possible (perhaps it could be affected by a user setting).
Guest almost 3 years ago in Data Archive 2 Declined

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Guest over 1 year ago in Data Archive 2 No status

Add a Confirmed Write methods

All methods exposed through AF SDK and other Developer Technologies are "fire and forget". Please add methods, at least for time series data, which return when the data has been processed. A write operation that returns when data has been process...
Guest almost 3 years ago in Data Archive 1 Declined

Enable Data Fanning for PI Collectives through PI System Management Tools

Currently, PI System Management Tools supports buffering but not data fanning (does not send data to all collective members). When using a PI Collective, customers would like to make changes to PI Point values in Archive Editor in the Primary Dat...