Data Archive

Showing 126 of 1349

Extract events from buffer queue files or offline archives

Currently, the procedure to recover buffer queue files consists of parsing the queue file into a temporary archive and then merging this archive with the registered archive files that overlap with the impacted period. This final merge requires to ...
Guest over 3 years ago in Data Archive 1 No status

Event mode that applies NoReplace to snapshot as well

Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest over 3 years ago in Data Archive 2 No status

Option to install sample PI tags with simulator interfaces

Posted on behalf of a customer. As of PI Server 2018 SP3, simulator interfaces have been removed from the PI Server setup kit, and the default PI Points are no longer installed. These were very important to check if the server installation went w...
Guest over 3 years ago in Data Archive 0 No status

Separate priority setting for Data Read and Data Write

Data Read and Date Write (Buffering) from/to PI Data Archive is based on the priority settings in PI SDK and PSE. We have a architecture of 6 member PI collective and all the source data is not buffered to the individual collective. Hence for othe...
Guest over 3 years ago in Data Archive 2 No status

Include usernames in pidiag -xa export of PI Archive audit trail

As a PI Administrator in a regulated environment, it would be helpful if the Archive audit trail data exported by the pidiag -xa command included the username associated with each action. Currently, the pidiag -xa exports of archive audit logs do ...
Guest over 3 years ago in Data Archive 1 No status

PI SMT's Current Values plug-in should have an option to not display comma separators for large numbers.

PI System Management Tools currently displays comma separators for large numbers. For example: 1,000,000. As a PI admin/user, it would be beneficial if there was an option to remove these commas.
Guest over 1 year ago in Data Archive 0 No status

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Guest almost 2 years ago in Data Archive 2 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Guest over 1 year ago in Data Archive 0 No status

PI SMT's Archive Editor should support manually adding NULL values

Archive Editor in PI System Management Tools should support writing NULL values (ie, empty strings). This is currently supported by other PI Clients. For example, it is possible to write empty strings using PI System Explorer as well as using a PI...
Guest 12 months ago in Data Archive 0 No status

As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.

Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...