Currently, if you want to store predictions for 1 day, 2 days, 3 days, etc. into the future, you must create a different PI tag for each distance into the future.
Future data tags should support 2 timestamps: the timestamp that the predicted valu...
Extract events from buffer queue files or offline archives
Currently, the procedure to recover buffer queue files consists of parsing the queue file into a temporary archive and then merging this archive with the registered archive files that overlap with the impacted period.
This final merge requires to ...
Guest
over 2 years ago
in Data Archive
1
No status
Option to install sample PI tags with simulator interfaces
Posted on behalf of a customer.
As of PI Server 2018 SP3, simulator interfaces have been removed from the PI Server setup kit, and the default PI Points are no longer installed. These were very important to check if the server installation went w...
Guest
over 2 years ago
in Data Archive
0
No status
Separate priority setting for Data Read and Data Write
Data Read and Date Write (Buffering) from/to PI Data Archive is based on the priority settings in PI SDK and PSE. We have a architecture of 6 member PI collective and all the source data is not buffered to the individual collective. Hence for othe...
Guest
over 2 years ago
in Data Archive
2
No status
Include usernames in pidiag -xa export of PI Archive audit trail
As a PI Administrator in a regulated environment, it would be helpful if the Archive audit trail data exported by the pidiag -xa command included the username associated with each action. Currently, the pidiag -xa exports of archive audit logs do ...
Guest
over 2 years ago
in Data Archive
1
No status
As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.
Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...
Guest
over 2 years ago
in Data Archive
1
No status
PI DA Server should allow for more flexibility in terms of the format of archived data. A big advantage would be if PI could archive two timestamps per event. One timestamp will come from whatever the data source is (PI Interfaces, fiels devices, ...
It would be nice to have threshold attributes for pi points. Then we could configure that values received from the source outside this limits would be ignored (not stored), substituted by the respective threshold value or even by an "Over\Under Ra...
Event mode that applies NoReplace to snapshot as well
Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest
over 2 years ago
in Data Archive
1
No status
The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.