Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 830

Replace function to be added in AF analysis

It would be interesting to add the Replace function (like the one in StringBuilder) directly in AF Analysis
Gael over 2 years ago in Analytics & Calculations 2 No status

Keep escalating Notification until it is acknowledged, even if no longer active

I would like the option to configure a Notification to continue to be escalated until it has been acknowledged, even after the trigger condition has become false and the Notification is no longer active.
Guest over 2 years ago in Notifications 2 No status

Propagate renames of event frame generation analyses to the notification rules

Currently, if an event frame generation analysis is renamed, all notifications rules that use it will display an error message, saying that the event frame generation analysis might have been renamed or deleted. This message is fine for deletions...
Guest over 2 years ago in Notifications 1 No status

Exclude analysis output attributes when the analysis is suspended

When the PI Analysis service determines an Analysis should be Suspended, it should also set any output Attributes to be Excluded. As the Analysis is Suspended, it will not output any results and if it has always been Suspended, the output Tags wil...
Guest over 2 years ago in Asset Framework (AF) 2 No status

Force Shift warning is misleading

When force shifting an archive, the following message is displayed: "Warning: This shift will clear data from the target archive. Are you sure you want to force an archive shift on to a new archive?" When Auto Archive Creation is enabled (having...
Guest over 2 years ago in Data Archive 0 No status

Add reset and hold triggers to SQC analytics

Add the triggers to SQC rules to reset or hold the SQC rule. When monitoring a periodic or batch based process, a user needs to be able to hold the SQC rule or put that rule in a hold state until the process resumes. Without this feature, virtuall...
Guest over 2 years ago in Analytics & Calculations 0 No status

PI Point User Settings in AF Client

The Suggested PI Point Name configuration item in the AF Client should be able to be set on a AF Server basis instead of a User basis, at least as the initial default. There are default parameters we need to enforce from an enterprise/site level b...
Matt Voll over 2 years ago in Analytics & Calculations 7 No status

Allow exclusion of message types when searching PI Message logs

As a PI System administator of a busy PI Data Archive, I find that my message logs are unwieldy. I can miss important messages in the flood of connection messages and other repetitive messages. I would like to be able to search my message logs whi...
Guest over 2 years ago in System Management 0 No status

Export/Import Contact Groups and/or Delivery Endpoints to XML from PI System Explorer

Please allow one to export, and import, to XML from PI System Explorer Contact Groups and/or Contact Delivery Endpoints.  Doing this with AFExport.exe and AFImport.exe on the AF Server is cumbersome and restrictive.
Guest over 2 years ago in Asset Framework (AF) 2 No status

Add filters support to AF Summary calculations

PI-DataLink allows for filtering of aggregate calculations, for example to get the average inlet temperature of a compressor when the turbine speed is > 1000 RPM. This is not possible with AF. The KB01120 article does not work and is very mess...
Guest over 2 years ago in Asset Framework (AF) 6 No status