Showing 842

Auditviewer separation of roles

I want to separate the security roles between 1) the ability to run an Auditviewer report and (potentially) associate a change control record to a configuration change and 2) the PI Admin Role in order to minimize security risk.
Guest almost 3 years ago in Security 1 No status

We need a method to send pi message log to syslog server

Provide a configurable export of PI Message log to syslog server.
Guest almost 3 years ago in Security 0 No status

Have a consistent presence of a terminating \ in the PIHOME and PIHOME64 environment variables

By default, PIHOME is "C:\Program Files (x86)\PIPC" and PIHOME64 is "C:\Program Files\PIPC\". For new installations, please consider either having the terminating \ on both or removing the terminating \ from both. The current inconsistency can con...
Guest almost 3 years ago in Installation 0 No status

Remove PI System Explorer (Legacy 32-bit) from PI AF Client

When PI AF Client is installed, it includes a program called "PI System Explorer (Legacy 32-bit)". Please remove this from PI AF Client. The continued support of 32-bit PI AF SDK makes sense, since 3rd-party programs may still depend on the 32-bit...
Guest almost 3 years ago in Installation 2 No status

The PI Server Installation kit should list the PI software requirements sooner in the install

As a PI System Administrator, I would like the PI Server Installation kit to list out any PI Software that will be included with a selected role or feature before the Summary step so that I can determine what will be installed without having to fi...
Guest almost 3 years ago in Installation 0 No status

Pi Point removal tied to AF Element Delete

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/5268-pi-point-removal-tied-to-af-element-delete We need the ability to remove PI Points when deleting AF Elements in a single command execution like Builder does PI Point creati...
Guest almost 3 years ago in General 1 No status

Buffer subsystem to handle deleted values

Can buffer subsystem be enhanced to manage value deletions from tags? We have a collective and utilize buffering to send data to both collective members however we have to jump through hoops to delete data from both collective members. It would be...
Guest almost 3 years ago in Data Archive 1 No status

smarter calculation of PI Backup required free space

When backfilling tags from AF its very easy to update many archives. I would like the backup script to only require free space for archives that don't exist in the target folder. We have periodic incremental backup failures do to a lack of free di...
Guest almost 3 years ago in Data Archive 3 No status

Replace the batch (.bat) scripts in the %PISERVER% folder with PowerShell (.ps1) scripts

This replacement is appropriate for several reasons: PowerShell is easier to read and is a more powerful language than the batch language. Batch scripts are best used in Windows, whereas PowerShell is cross-platform. This replacement will support ...
Guest almost 3 years ago in Data Archive 1 No status

Optimize and compress non-primary historic archive files

Currently, the same file format is used for primary and non-primary historic archive files. This does not make much sense since the two types are used very differently. For the primary archive: Write operations should be fast since it is collectin...
Guest almost 3 years ago in Data Archive 4 No status