All ideas

Showing 830

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest over 2 years ago in Analytics & Calculations 0 No status

Shift based sending

As a Plant manager I would like to assign specific people to receive notifications based on the time of day since they work in shifts and different people are responsible for the equipment at different times of the day.
Guest over 2 years ago in Notifications 0 No status

Notification Screenshot Custom URL

we're examining the new functionality of attaching screenshots to emails sent by PI Notifications. The problem we're having is that we would like to use an attribute value for the URL. This does not seem to be possible. In the configuration, only ...
Guest over 2 years ago in Notifications 1 No status

Notifications format editor "Create a Link" tool should allow the base address to be substituted from a URI Builder Data Reference attribute

As a Notifications user, I would like to be able to use certain features of the "Create a Link" tool for editing Notifications Formats, like the ability to display alternate text and add url parameters, when the url is held in an attribute that is...
Guest over 2 years ago in Notifications 1 No status

XML or other flat file Delivery channel

Would like to see the ability to create XML or other flat files from PI Notifications as was available in previous versions. We have seen cases where the network that the PI system resides on is locked down to the point that only flat files can be...
Guest over 2 years ago in Notifications 0 No status

Ability to modify SOAP xml format

There are some cases when the sender wants to modify the format of the SOAP xml itself. Currently Notifications service constructs a XML request including all the variables provided by the wsdl.
Guest over 2 years ago in Notifications 0 No status

Allow PIWorld and piusers to be deleted

Nobody should be using the "PIWorld" PI Identity or the "piusers" PI Group. The most that we can do at the moment is disable them. It would be much better if we can just delete them and never look back.
Guest over 2 years ago in System Management 2 No status

Support for Windows event logging

As a system administrator, I need to integrate PI System logging into my SEIM, so that I can manage PI System events consistent with other applications in a centrally managed system. Most PI System applications leverage the Applications and Serv...
Guest over 2 years ago in System Management 1 No status

Substitution parameter from root

As an AF administrator, I want to configure templates with Point Creation using Substitution Parameters that can retrieve names and values from an element relative to the root element and working it's way down to the element wanted. A way for this...
Guest over 2 years ago in Asset Framework (AF) 3 No status

Add TimeRangeMethod to StringBuilder DataReference or automatically use StartTime when used on Event Frames.

A frequent  PI Square problem regards using StringBuilder DR on event frames and the user wants to see the referenced element's attribute at the StartTime of the event frame.  Something like a TimeRangeMethod or  UseStartTime flag w...
Guest over 2 years ago in Asset Framework (AF) 7 No status