Showing 849

Allow PIWorld and piusers to be deleted

Nobody should be using the "PIWorld" PI Identity or the "piusers" PI Group. The most that we can do at the moment is disable them. It would be much better if we can just delete them and never look back.
Guest almost 3 years ago in System Management 2 No status

Support for Windows event logging

As a system administrator, I need to integrate PI System logging into my SEIM, so that I can manage PI System events consistent with other applications in a centrally managed system. Most PI System applications leverage the Applications and Serv...
Guest almost 3 years ago in System Management 1 No status

Substitution parameter from root

As an AF administrator, I want to configure templates with Point Creation using Substitution Parameters that can retrieve names and values from an element relative to the root element and working it's way down to the element wanted. A way for this...
Guest almost 3 years ago in Asset Framework (AF) 3 No status

Add TimeRangeMethod to StringBuilder DataReference or automatically use StartTime when used on Event Frames.

A frequent  PI Square problem regards using StringBuilder DR on event frames and the user wants to see the referenced element's attribute at the StartTime of the event frame.  Something like a TimeRangeMethod or  UseStartTime flag w...
Guest almost 3 years ago in Asset Framework (AF) 7 No status

Option to reconcile templates during xml import

Suppose the following scenario: a user has 2 AF databases (a development and a production one), both containing same version of a template. The user deletes a few attributes and analyses from one element template (development), exports the xml and...
Guest almost 3 years ago in Asset Framework (AF) 2 No status

Longer passwords PI AF Table Connector

This is really a bug/security risk; but the support team has requested that a "Customer Voice" be raised. Support passwords longer than 15 characters in the PI AF Table Connector.
Guest almost 3 years ago in Asset Framework (AF) 0 No status

Add array sorting function to AF Analytics.

This would also enable calculation of percentiles. Percentile calculation would also be possible if the user could use nested substitution parameters in array functions. For example: RecVals := RecordedValues('Attribute1', start, end) CountLowe...
Guest almost 3 years ago in Asset Framework (AF) 0 No status

Archive corruption detection

For the moment some Archive corruption are not detected automatically by PI DA. For example error -15000 due to archive corruption. Please enhanced the archive corruption detection because we have more and more long history and it can become diffi...
Guest over 2 years ago in Data Archive 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Guest almost 2 years ago in Notifications 1 No status

Ability for admins to restrict PI Data query to 2 years at a time.

I would like to restrict PI Vision users from pulling data for more than 2 years at a stretch. This setting should also restrict the PI Data link as well. This will make the software more robust to query timeout. Just let users know they need to a...
Ronald Main almost 2 years ago in Data Archive 0 No status