Would like to see the ability to create XML or other flat files from PI Notifications as was available in previous versions.
We have seen cases where the network that the PI system resides on is locked down to the point that only flat files can be...
Guest
almost 3 years ago
in Notifications
0
No status
There are some cases when the sender wants to modify the format of the SOAP xml itself. Currently Notifications service constructs a XML request including all the variables provided by the wsdl.
Guest
almost 3 years ago
in Notifications
0
No status
Nobody should be using the "PIWorld" PI Identity or the "piusers" PI Group. The most that we can do at the moment is disable them. It would be much better if we can just delete them and never look back.
As a system administrator, I need to integrate PI System logging into my SEIM, so that I can manage PI System events consistent with other applications in a centrally managed system.
Most PI System applications leverage the Applications and Serv...
As an AF administrator, I want to configure templates with Point Creation using Substitution Parameters that can retrieve names and values from an element relative to the root element and working it's way down to the element wanted. A way for this...
Add TimeRangeMethod to StringBuilder DataReference or automatically use StartTime when used on Event Frames.
A frequent PI Square problem regards using StringBuilder DR on event frames and the user wants to see the referenced element's attribute at the StartTime of the event frame. Something like a TimeRangeMethod or UseStartTime flag w...
Suppose the following scenario: a user has 2 AF databases (a development and a production one), both containing same version of a template. The user deletes a few attributes and analyses from one element template (development), exports the xml and...
This is really a bug/security risk; but the support team has requested that a "Customer Voice" be raised.
Support passwords longer than 15 characters in the PI AF Table Connector.
This would also enable calculation of percentiles.
Percentile calculation would also be possible if the user could use nested substitution parameters in array functions. For example:
RecVals := RecordedValues('Attribute1', start, end)
CountLowe...
Ability for admins to restrict PI Data query to 2 years at a time.
I would like to restrict PI Vision users from pulling data for more than 2 years at a stretch. This setting should also restrict the PI Data link as well. This will make the software more robust to query timeout. Just let users know they need to a...
Ronald Main
over 1 year ago
in Data Archive
0
No status