Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

All ideas

Showing 849

Notifications for events in the past

Currently notifications are not triggered (send) by events that are more than 72 hours in the past. For me it is necessary to get notifications from events in the (endless) past. Ideally I would like to configure for each notification separately t...
Guest almost 3 years ago in Notifications 8 No status

PI Analysis Service should pick up change in Cache Refresh Interval of AF Tables

It would be nice if the PI Analysis Service could pick up a change in the Cache Refresh Interval of any AF Table being referenced by input attributes with a table lookup data reference. Currently, a service restart is required.
Guest almost 3 years ago in Analytics & Calculations 5 No status

Ability to send a notification without being triggered by an event frame

As a notification user I want to receive a report on daily or weekly basis but I don’t want to store any associated data about it like the event frame information or the notification history since I use event frames for other purposes and I don’t ...
Guest almost 3 years ago in Notifications 3 No status

Composite element templates

As an user I want to be able to create a template hierarchy (parent-child) all at once, so that I can easily create a hierarchy representing related assets. For example, create a motor, gearbox, compressor train with a single template that actuall...
Guest almost 3 years ago in Asset Framework (AF) 4 No status

Allow different naming for Parent and Child Event Frames

Allow a different naming pattern for the child event frames. End result would have the long, uniquely named EFs in the Parent EF as usual, but the Child EFs could have a simplified name, like the level of an alarm that is pulled from an attribute ...
Guest almost 3 years ago in Event Frames (EF) 7 No status

Modernize PI system logging

PI system logging is currently fragmented across multiple location. This makes troubleshooting and log correlation difficult. Solution: Make logging consistent across all PI system applications. (ex: all logs stored in windows event log; all logs ...
Guest 12 months ago in System Management 1 No status

Improve Data Cache Performance by parallelizing Data Archive update fetches

Currently, when the Data Cache is signed up for updates on multiple data archives, updates from each archive are fetched in series, one after another. When there are many data archives involved (especially if they are geographically dispersed) thi...
Guest over 2 years ago in Analytics & Calculations 1 No status

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
Guest 10 months ago in Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
Guest 10 months ago in Asset Framework (AF) 1 No status

Offer extended support for PI ProcessBook for security updates only past 2022

As other vendors do, offer customers the option to purchase extended support for PI ProcessBook for security updates only past 2022 for at least one year, and reevaluate annually based on number of customers interested. This would only apply to s...
Guest almost 3 years ago in General 0 No status