Web Service Configuration - Dynamic "Path" for the JSON Body

Allow free-form JSON construction. Maybe not replace the simple JSON guide that is the only entry form now, but free-form would allow the kind of flexibility that would empower the user. This would allow a single template to be used, rather than...
Guest almost 3 years ago in Notifications 2 No status

Summary Notifications

Add the ability to send one email with multiple notifications inside it. User can get overwhelmed if they're getting a lot of SQC notifications at once, would be nice if it was one email with the various notifications listed. This would work: Ev...
Guest almost 3 years ago in Notifications 0 No status

PI Notification periodic schedule

To update the last send time of the notification to be based on the configured time in the periodic schedule to resend the notification but not the time of the last notification sent.
Guest almost 3 years ago in Notifications 0 No status

Schedule PI Notifications "outages"

It would be very useful if an "outage" for PI Notifications could be scheduled. We often start or finish maintenance well outside of work hours, and the flood of PI Notifications can annoy users who are not on site. Ideally we could set an outage ...
Guest almost 3 years ago in Notifications 1 No status

Show "Subscriber Escalation Timeout" parameter in PI System Explorer

In PI System Explorer's UI, you can configure time intervals for escalation groups. If the SubscriberEscalationTimeout parameter is different from the escalation group's interval, the notification will not deliver on the right interval and there w...
Guest almost 3 years ago in Notifications 0 No status

add support for client certificate authentication in PI Notifications

Add support for client certificate authentication in PI Notifications
Guest almost 3 years ago in Notifications 1 No status

Easy selection of PI Archives to Backup

Currently, if we want to do a backup of an archive in SMT, we have to tick it. But the customer may has like 500 archives and wants to copy 100 of them. There is currently no friendly-user way to select multiple archives (without unregister them) ...
Guest almost 3 years ago in System Management 0 No status

Add ability to honor archive list file locations when adding new server to PI HA Collective

When adding a new server to a PI HA Collective, all archive files selected to be included in the initialization are copied and registered with the new server in one defined location in collective manager.  This can create more manual work for...
Guest almost 3 years ago in System Management 1 No status

PI SMT - Archive Editor Improvements

Why is the second server of all selected servers the default selected server for the archive editor? (C# index 1 instead of 0?) If I leave the Tagname empty and press the search button the tag search dialog opens fine. But if I enter some text at...
HolgerJoistOmv almost 3 years ago in System Management 0 No status

Increase Box Length for Tagname Field in Archive Editor

The Tagname field visible length should be increased within Archive Editor in System Management Tools. The full tag name is limited and cannot tell what is listed because the name is cut off. (See screenshot and steps listed below.) Steps to repr...
Guest almost 3 years ago in System Management 0 No status