Right now BadVal can only check one variable or Expression. So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
Currently, AF search results can only be sorted by a single field. It would be useful to have the capability to specify 2 (or more) SortField values so that the order of results can be guaranteed in the result of a tie.
For example, being able to...
It would be nice to have the ability to drag and drop the value at end time of an attribute in the message format of a Notification. We can do this with the value at start time and the value at send time, but not the value at end time. There...
Guest
almost 3 years ago
in Notifications
1
No status
Currently, the only way to acknowledge a notification in PI Notifications (2.X) is to acknowledge the event frame in PI Vision. Not all customer's have PI Vision.
Therefore, the Acknoledgment Site from PI Notifications (1.X) should be upgraded t...
Guest
almost 3 years ago
in Notifications
2
Declined
Use %Duration% with Formula Data Reference as Best Practice for EF Duration Attribute (AF 2017 R2+)
This is a followup to discussions with Roger Palmen and Rick Davin about their excellent writeups on the topic of EF Duration attributes; see Event Frame duration - easy way in AF2.6 or higher & Duration attribute on an Event Frame - Part 1 , ...
As an administrator, I would like to be able to backfill data that crosses over a versioning event
Use case:
1. An element has an attribute that looks up information on equipment configuration (ex: a pump rate)
2. Due to an equipment change, the lookup table and the element were increased in version
3. A backfill needed to be performed o...
There are other similar ideas out there on this site but I would like to see the ability to skip numbers in the Digital States Enumeration. We have areas of the plant that have states which don't map well to a 1,2,3.... set of states. Some are bit...
Unfortunatly PI Notfication is an very old tool.
The Tool is very old and slow.
Improvements are needed.
Improvements needed:
1. Performance Update for the engineering tool in the AF is very poor
2. Functionality to send an event to an webapi is...
Guest
almost 3 years ago
in Notifications
1
No status
Buffering Manager should have tuning parameter for Points with Post Errors
Right now there is a PerfMon counter for Buffer Health. It's either 0, 1, or 2. That's not helpful because it doesn't tell you what is wrong. There are other PerfMon counters for Remaining Queue capacity and Points with Post Erro...
Guest
almost 3 years ago
in General
1
Tell us more