Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Ideas

Showing 459 of 1341

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Guest over 1 year ago in Analytics & Calculations 0 No status

Provide more user-friendly way to configure backups

As a PI admin, I wish there was a GUI way to set up backup tasks instead of needing to go to the command line to set up my backup task. (FS, 415 hrs) As a PI admin, I have a hard time setting up backup scripts to write to an external data source...
Guest about 3 years ago in Data Archive 0 Declined

Store thread history along with connection history in the server

Storing the thread history(pibasess/piarchss etc) along with the connection history will help to better understand and troubleshoot issues on the archive and will serve as a kind of auditing on the behavior of connections.
Guest about 3 years ago in Data Archive 0 Declined

PI collective with shared archives

Allow the Primary Data Archive server read-write access to any shared archives. All Secondary data archive servers would have read-only access. This would fix case Case # 925881. We have tags with old timestamps, for example, environmental limits,...
Guest about 3 years ago in Data Archive 0 Declined

Ability to view Instrument Tag and Point Source attributes within PI SMT > Data > Current Values pane

Feature request would be to include Instrument Tag and Point Source attributes to be view-able through the Data > Current Values pane of PI SMT.  This would allow administrators and users the ability to quickly diagnose and/or trace PI Poi...
Guest about 3 years ago in Data Archive 0 No status

Compress archives that are backed up using "Copy"

Currently, when a "copy" backup occurs, the archives are copied as-is. Archive files take up a lot of space, but they also compress very well (if you deleted a bunch of tags without creating as many new ones), and since archive backups are rarely ...
Guest about 3 years ago in Data Archive 0 No status

Improve PI Server Installation kit: disk space requirements should include the minimal PI Backup

When calculating the disk space requirements on a recent upgrade the drive was expected to have only 138 MB installed. But the install failed due to not enough disk space on the drive because the minimal backup needed a certain amount of disk spac...
Guest about 3 years ago in Data Archive 1 No status

PI AF Link & PIBatch - Ability to uninstall it

PI AF Link is not included in PI 2018 but it would be good to be able to remove the link during an upgrade. (not possible today https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000027668). Same for PIBatch which cannot be unins...
Guest about 3 years ago in Data Archive 1 No status

AI Detection for Stale Points

As a PI System administrator, it would be helpful if the PI Server had an artificial intelligence or machine learning system which could recognize the normal updating patterns of a PI Point and report when a tag was not receiving updates properly ...
Guest about 3 years ago in Data Archive 0 No status

Recover data from current time moving backwards

Recover data from the current time back rather than start of a data gap to now (current time). The most important thing is to get current data immediately.
Guest about 3 years ago in Analytics & Calculations 1 Declined