Fix for KI: EventFrame Extended property not removed after EF is closed
The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Use Case: calculating which Shift is working within a rotating-shift cycle, which must the follow Daylight Savings Time offset.
This function is available in the Performance Equation library, but not in AF. The function itself is simple once one ...
PI Analysis Service should pick up change in Cache Refresh Interval of AF Tables
It would be nice if the PI Analysis Service could pick up a change in the Cache Refresh Interval of any AF Table being referenced by input attributes with a table lookup data reference. Currently, a service restart is required.
As a PI user, I want to be able to visualize and analyze the SQC violations that are generated by the SQC rules.
The ability to save SQC outputs such as Mean, median, mode, stdev, Cpk, max, min, 1-5 sigma zones, ucl, lcl in the following ways
...
Order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer
I would like to be able to order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer after retrieving a list of analyses through a search/filtering. This could be done by clicking on the Name column.
Trigger automatic recalculation for snapshot changed values
As for now, automatic recalculation is not triggered by changes on snapshot (KB01790), which means auto-recalculation does not work with snapshots values.
The idea of it doing otherwise is to help users that mistakenly added a wrong new event to ...
Compare timestamps and output most recent value in child elements to parent element
From a varying number of child elements (all sharing the same template), I want to find the most recent timestamp of a same template-based attribute, and output the value with timestamp to an attribute in the parent element.
In addition, constant...
Integrate matlab and AF Analytics so that scheduling of an analytic can be configured in PI to trigger calculations and other analyses being executed within Matlab (and written back to PI).
As a user, I would like to configure my rollups to display a value only if the quality of my inputs reaches a minimum % good (configurable). Currently, it's not clear which inputs are used in the rollup calculation- even if some inputs have bad va...
Using the Max Rollup function - I would like to know which element provided the maximum value and output this as well so I can historize the information.