Event Frame Start and End Timestamp relative to trigger
With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation
As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Use a PI tag with point type timestamp as the retrieval method on an EF attribute.
Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Let Start Trigger severity set the EventFrame severity
Currently the Severity of the EF is set on the template. The severity of a start trigger allows to create child events.
I want to have the ability to have the severity of the start trigger set the severity of the generated EventFrame. In that way...
The "True for" time of event frame generation analyses should not consider the extrapolation after the snapshot event
PI assumes that the value of a PI Point from its snapshot event up to now is equal to the snapshot value. This extrapolation is not necessarily a good representation of what the interpolation will look like when new data arrives.
The extrapolatio...
Event Frames Scalability - For Customer Advisory Lab Scenarios
#of assets (in this specific scenario): 500-1000
EF Count: Generation rate of 25,000/day peak, would like to historize for 1+y = 9,000,000 events+
Attributes: 5-10 attributes/event (static or PI Point)
Flat Hierarchy
Queries: EF are alarms or ...
Store event frame start and end time as DateTime to allow sub-millisecond duration event frames
Because event frame start and end time are stored as a bigint datatype in PIFD.dbo.AFEventFrame, the precision only seems to be to the nearest millisecond. This is a problem for sub-millisecond event frames. Why aren't event frame start and end ti...
Add an Annotations column to the Event Frames search window
It would be nice to add an Annotations column to the search page of Event Frames, so that I can better analyze them directly from PSE for administration purposes
AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record.
Due to ...
Keeping old events that have been manually worked on in case of Recalculation/Backfill
Case 1.
There are some EFs that should be acknowledged and commented by equipment owners. In Pharma World, these comments qualify as GxP and shall not be deleted. Whereas Event Frames generated by analysis can sometimes due to data coming late or...