Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Asset Framework (AF)

Showing 379 of 1336

If the reference UOM of a UOM changes, relabel the sample conversion immediately

If you add or edit a UOM and change the reference UOM when the method type is "Simple", the sample conversion will not reflect this change unless the factor or the offset is edited. Instead, the change in the reference UOM should be reflected imm...
Guest about 3 years ago in Asset Framework (AF) 1 No status

Tool for SQL Security and Consistency Check for the PI AF Server

It is difficult to manage the AF security complexity and ensure proper authorizations so that there are no security holes.  I would like a built-in tool that can go through and check various aspects of AF/PIFD security and integrity and gener...
Guest about 3 years ago in Asset Framework (AF) 0 No status

PSE auto generates many dll files in plugins folder

PSE is generating lots of .dll files in this directory: C:\Users\[UserID]\AppData\Local\Temp\PlugIns Request these files to be cleaned up automatically (perhaps after each PSE user session) to conserve disk space.
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Dynamic Email Delivery Endpoint should support multiple recipients from a comma or semicolon separated string

Dynamic Email Delivery Endpoint should support multiple recipients (from a comma or semicolon separated string). This would allow us to simplify many templates. Specifically, this would allow use cases such as a single element template with an “A...
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Sort Dates in PI System Explorer correctly

Very small/minor request: PI System Explorer Grid Control needs to sort Date Attributes by Date and not by String. Example of current sorting: 1/1/2018 11/1/2017 2/1/2016 3/1/2015 Proposed sort: 3/1/2015 2/1/2016 11/1/2017 1/1/2018
Guest about 3 years ago in Asset Framework (AF) 1 Declined

Display EndOfStream value instead of Current value for Future data for attributes in AF Explorer

Display EndOfStream value instead of Current value for Future data for attributes in AF Explorer
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Allow the boxes in PI System Explorer's Security Configuration window to be vertically resized

In PI System Explorer → File → Database → Edit Security, the border under the "Items to Configure" box and above "Identities" and "Permissions for" should be adjustable. This would allow "Items to Configure" to grow and the other 2 boxes to shrink...
Guest about 3 years ago in Asset Framework (AF) 0 No status

Allow multiple child attribute templates to be deleted at once in PI System Explorer

Currently, if you select multiple child attribute templates and right-click on them, the Delete option will not be available. However, nothing stops the user from deleting the child attribute templates individually.
Guest about 3 years ago in Asset Framework (AF) 2 Declined

Be able to change an element's template from the General tab in PI System Explorer

Changing an element's template would be easier if it could be done from the General after clicking on the element in PI System Explorer, similar to how the base template of element templates can be changed from the General tab. Template changes a...
Guest about 3 years ago in Asset Framework (AF) 0 Declined

Make PI System Explorer's "Choose Element Template" windows resizable and filterable by category

If you go to add a new element, a window that lists the element templates appears. This window is resizable but does not allow filtering by category. A similar window appears if you go to change an existing element's template. This window is not r...
Guest about 3 years ago in Asset Framework (AF) 0 Declined