Skip to Main Content
AVEVA Product Feedback


ADD A NEW IDEA

Asset Framework (AF)

Showing 247

Rollup Analysis - Filter Attribute Names at both Root & Child Level

Requesting the ability to be able to filter at BOTH the root level (parent attribute) and child level (child attribute) when doing a rollup analysis. If you have the same child attribute names under different parent attributes (i.e. Children: YTD...
Guest over 3 years ago in Asset Framework (AF) 0 No status

UOM field should accept substitution parameters

It would be nice if the UOM field of an AF Attribute would accept substitution parameters. This way if an attribute is a reference to another, the UOMs could also be linked. If the UOM is updated on the source, it would also get updated in the ref...
Guest over 3 years ago in Asset Framework (AF) 0 No status

Improve PSE's Import/Export/Copy functionality to allow conversion of referenced elements to standalone elements

Presently, when copying sections of an AF hierarchy that contain dependencies (element templates, referenced elements, attributes that use these references), the dependencies that are located under the AF branch being exported will successfully be...
Adam Bolin 4 months ago in Asset Framework (AF) 0 No status

Pi System Explorer: Display Check-In History Per User

I would like to be able to see a log of when users checked in changes to the system in PSE. I recently checked in changes to our PSE system and around the same time, the CPU pegged of SQL server and the analyses slowed way down and other functiona...
Jonathan Gibbs 8 months ago in Asset Framework (AF) 0 No status

Allow access to Attribute Timestamp without using Analysis

It would be very helpfull if we could access not only attribute values but also their timestamp in formulas, string builder, etc.. For example, this would help calculate staleness of a value, or it could be used to set a PI Point Attribute to show...
Guest over 3 years ago in Asset Framework (AF) 2 No status

Change UoM, Display Digits of attribute independently of element template

Currently, if an attribute is created with a Unit of Measurement in an element template, it is not possible to change the Unit of Measurement in the element created from that template. If no UoM is given in the template, then the UoM of the under...
Christoph Rose over 3 years ago in Asset Framework (AF) 2 No status

Substitution Parameters for PI Point Exdesc

I would like to have an out of the box way for an attribute to display a pipoint exdesc. One thought would be able to have a substitution parameter that would point at the pipoints exdesc.
Guest over 3 years ago in Asset Framework (AF) 0 No status

Allow internal AF Tables to be linked from one AF Database to another

In some scenarios, creating a linked table to an internal AF table is more appropriate than linking to an external table. For example, an internal AF table which contains a list of assets and their associated tag name may be applicable to multiple...
Guest over 3 years ago in Asset Framework (AF) 0 No status

Allow nested attribute references for String Builder Data References

As a PI System Admin, I would like to reference an attribute value as part of my attribute data references for a String Builder data reference. For example, suppose I have a parent asset 'Parent' with an attribute of 'XD5' and a child element 'Chi...
Guest over 3 years ago in Asset Framework (AF) 0 No status

Ability to move an AF element within the hierarchy in PSE by right-clicking on the element

When moving an AF element within the hierarchy in PSE using the "Shift key + Drag and Drop" approach, it can cause to create an Element reference if the release of the "Shift key" is done before dropping the element. Having the option of right-cl...
Guest over 3 years ago in Asset Framework (AF) 0 No status