Showing 128 of 1364

Export Multiple Audit Logs into one XML/TXT File

The pidiag -xa utility doesn't support selecting a folder location and exporting the contents to a single XML/TXT file. This would be very helpful for bulk auditing actions.
Guest almost 3 years ago in Data Archive 1 No status

To bring back Archive Activity Grid feature

To bring back Archive activity grid which brings many insights for the administrators for archive health monitoring. My suggestion is to maybe enhance it and provide a UI base functionality, similar to PI AuditViewer.
Guest over 1 year ago in Data Archive 0 No status

Ability to reprocess individual points to handle digital set changes

Current functionality: When changing a point from digital set A to digital set B, all events going forward will use digital set B. If you do not reprocess the archives, the events that were archived before the digital state was changed remain asso...
Guest over 1 year ago in Data Archive 0 No status

Store a timestamp of when an event enters the archive database

We have a use case that could be solved very easy if we have had this as a column in the data archive. Use case: We have made PI data availible through an own made API to our clients. They use this API to fetch data from our database and into thei...
Ole Dybsjord Skarsvag over 3 years ago in Data Archive 0 No status

Remove grayed out PI Tag Configurator link in newer versions of SMT

No description provided
Guest over 3 years ago in Data Archive 1 Declined

Backup pre-commited

As a Pi Admin, it would be usefull to be able to locate the Precommit directory used during the PI backup process to a different location from the Backup directory
jerome.boudon over 3 years ago in Data Archive 0 Declined

Confirm connection before writing to PI DA

No description provided
Guest over 3 years ago in Data Archive 1 Declined

Changing PI Data Archive Security Slider

No description provided
Guest over 3 years ago in Data Archive 1 Declined

Repeatedly loop future data

Customer would like to be able to loop future data.  For instance since yearly temperatures are about the same every year for a given month, it would be nice if only one set of the projections are stored somewhere and just repeated again and ...
Guest over 3 years ago in Data Archive 0 Declined

PI Archive File header should keep track of last modified recno

The PI Archive File should keep track of the last modified RecNo. This would make cases where historical archive last modified times are updated (and potentially causing large backups) much easier to track down. In particular, this feature combin...
Guest over 3 years ago in Data Archive 0 No status